Supplied By www.heating spares.co Tel. 0161 620 6677
16 INSTALLATION - SIDE FLUE
Manual No. 405/0101
INSTALLATION - SIDE FLUE - PAGE 16
front panel just below the depression. See Fig. 19.
2.
Remove the four screws (two at the top and two at the bottom) securing the inner case front panel and lift off the panel.
See Fig. 19.
Note:
When the inner case front panel is removed, the four case seal housing channels are not secured to the boiler as
they are retained in position by the front panel. Ensure that they are correctly fitted over the chassis edges before the
front panel is replaced.
3.
Remove the two screws securing the fan assembly to the flue hood. Withdraw the assembly, disconnecting the fan
motor and pressure switch leads. See Fig. 20.
4.
Lift the boiler into position over the wall mounting plate. The boiler has two brackets on the back of the chassis at the
top, these should be located on top of the wall mounting plate to take the weight of the boiler.
5.
Secure the boiler to the wall mounting plate using the four M6 hex. hd. screws, supplied with the boiler.
6.
Remove the four screws securing the transit cover to the bottom of the boiler, see Fig. 19 and discard the cover and
screws.
7.
Remove the four screws and sealing plate from the side of the chassis from which the flue is to exit. Discard the sealing
plate but retain the four screws.
8.
Place the rubber sealing ring, supplied with the flue/terminal assembly, in position in the opening in the chassis side as
shown in Fig. 20. Ensure that the cut-away is at the bottom, that the groove in it is located correctly over the chassis
side and that the holes line up with the fixing holes in the chassis side.
9.
Secure the sealing ring in position with the clamping plate, supplied with the flue/terminal assembly, using the four
screws previously removed from the chassis side. Ensure that the cut-away is at the bottom.
10. Select the appropriate side panel, see Fig. 29, through which the flue is to exit, remove the edge clips and push out the
round infill panel.
Locate the side panel over the two fixings at the side of the boiler chassis against the wall. Secure the panel in position
to the front of the boiler, at the top and bottom, using two of the No.8 x 12 lg. countersunk hd. screws supplied with the
boiler.
Fig. 20