12
Operating Instructions
US
FC
ESM
PTB
TR
RU
UK
MON
VIE
HE
AR
JPN
KOR
CHS
CHT
THA
ON/OFF lights up red.
Power supply/domestic connection flashes yellow.
Vehicle
is
off.
Control unit is off.
Reset is off.
The charging infrastructure of power
supply/domestic connection is limited.
Possible fault cause: Undervoltage or
poor grid frequency.
The charging process is interrupted.
The fault is automatically reset once the power supply/
domestic connection has stabilized.
e
If the fault persists, have the power supply/domestic
connection checked by a qualified electrician.
ON/OFF lights up red.
Power supply/domestic connection is off.
Vehicle
flashes
yellow.
Control unit is off.
Reset is off.
The vehicle charging system is faulty.
The charging process is interrupted.
The fault is automatically reset once the vehicle charging
system has stabilized.
e
If the fault persists, have the vehicle checked by a
specialist dealer/authorized Porsche dealer.
ON/OFF lights up red.
Power supply/domestic connection is off.
Vehicle
is
off.
Control unit flashes yellow.
Reset is off.
The supply or vehicle cable is defective.
Possible fault cause: The coding resis-
tances of the grid supply and vehicle
cable do not match.
The charging process is interrupted.
e
Have the grid supply or vehicle cable replaced by a
specialist dealer/authorized Porsche dealer.
ON/OFF lights up red.
Power supply/domestic connection is off.
Vehicle lights up red.
Control unit is off.
Reset is off.
The vehicle charging system is faulty.
The charging process is interrupted.
e
End the charging process at the vehicle and disconnect
the vehicle cable from the vehicle charge port.
e
Disconnect the charger from the power grid and connect it
to the power grid again after 60 seconds.
e
Re-start charging.
f
Refer to chapter “Starting charging” on page 8.
e
If the fault persists, have the vehicle checked by a
specialist dealer/authorized Porsche dealer.
ON/OFF lights up red.
Power supply/domestic connection flashes red.
Vehicle
is
off.
Control unit is off.
Reset is off.
There is overvoltage in the charging
infrastructure of the power supply/
domestic connection. The charging
process is interrupted.
e
Disconnect the charger from the power grid and connect it
to the power grid again after 60 seconds.
e
If the fault persists, have the power supply/domestic
connection checked by a qualified electrician.
ON/OFF lights up red.
Power supply/domestic connection is off.
Vehicle
is
off.
Control unit lights up red.
Reset is off.
The control unit has a technical fault.
The charging process is interrupted.
e
Disconnect the charger from the power grid and connect it
to the power grid again after 60 seconds.
e
If the fault persists, have the control unit checked by a
specialist dealer/authorized Porsche dealer.
Light indicators
Meaning
Remedy
9Y0.000.003.B-ROW.book Page 12