External  view  of  keypad  of  the  Spectroscopic  Radiation  Monitor  PM1403  and  functional 

purpose of the keys functional purpose are presented in Figure 6.2. 

 

 

 

1, 2

 –  

(

<<

,

 >>

) – quick switching between menu items or parameters; 

 

 

  (

MENU/SELECT)

  –  enter  selected  operation  mode  of  Spectroscopic  Radiation 

Monitor РМ1403 or highlighted option of the MENU; 

  

 

 (

MODE/BACK/OK)

 – open the list of Spectroscopic Radiation Monitor РМ1403 

operation modes. Exit or return to the previous operation mode or option.

  

 

Directional pad keys: 

– 

 

(UP), 6 

– 

 (DOWN) – 

vertical cursor scrolling along menu options;  

 

– 

 (LEFT), 8 

– 

 (RIGHT)

 – horizontal cursor scrolling; 

 

– 

  (ENTER)  –

  this  key  pressing  executes  the  EXECUTE  command,  and  enables 

switching to some program or option. 

 

Figure 6.2 – External view and functional purpose of Spectroscopic Radiation Monitor 

РМ1403’s keypad keys 

Содержание PM1403

Страница 1: ...LPHA BETA RADIATION DETECTOR BDAB OPERATION MANUAL...

Страница 2: ...1 Switch on off BDAB 15 6 2 Operation modes 17 6 2 1 Measurement mode of radiation flux density Measurement Mode 18 6 2 2 Measurement mode of radiation flux density Measurement Mode 20 6 2 3 Search m...

Страница 3: ...nation as well as other necessary information for correct instrument operation and full utilization of its capabilities BDAB is documented as follows according to state standard of manufacturer countr...

Страница 4: ...iation DER search ionization sources to prevent the illicit trafficking of radioactive materials The instruments are also used by specialists in various industries including agriculture transportation...

Страница 5: ...2 1 5 m 1 1 Cable No 2 1 25 m 1 1 Cable No 2 2 0 25 m 1 1 Cable No 3 1 filter 10 Handle 1 1 Nozzle1 1 Certificate2 1 CD Software Operation Manual 1 1 Package 3 1 1 Supplied by user request by separat...

Страница 6: ...500 E max Figure 3 1 Typical dependence of BDAB sensitivity relative to radiation energy 3 6 Measurement range of radiation density flux from 1 0 to 5 105 min 1 cm 2 3 7 Permissible limits of main mea...

Страница 7: ...dditional relative error of radiation flux density measurement don t exceed 30 under exposure of external gamma radiation field of 200 R h exposure rate and don t exceed 15 under exposure of external...

Страница 8: ...o electrostatic discharges test level 3 air discharge of 8 kV voltage contact discharge of 6 kV voltage performance criterion is resistant to is resistant to electromagnetic interference caused by rad...

Страница 9: ...as a monoblock BDAB is enclosed in a shockproof container Detector of radiation is based on the proportional counter with a mica window General BDAB construction is presented in Figure 4 1 a b a fron...

Страница 10: ...radiation detector 10 protection screen for input window of radiation detector Screen protects against mechanical injuries Center of the sensitive surface of BDAB is marked with the X sign on the fro...

Страница 11: ...radiation background A built in detector based on the proportional counter with a mica window is used to register and radiation flux density DER count rate Built in BDAB microcontroller processes imp...

Страница 12: ...manufacturer s name manufacturer s trademark serial number according to the numbering system of the manufacturer year of manufacture IP protection level state register mark 4 5 Package BDAB is packed...

Страница 13: ...tect the detector s entrance window radiation from mechanical damage to prevent breakdown of the BDAB detector Figure 4 1 positions 6 10 Always protect BDAB against blows and mechanical injuries corro...

Страница 14: ...ion 4 Check ability of BDAB to switch to every operation mode ALPHA LED lights blue indicates that the measurement mode of radiation flux density is activated Figure 4 1 position 1 BETA LED lights yel...

Страница 15: ...R LED will light on the front panel of BDAB Figure 4 1 position 4 1 alarm sounder produces sound audio alarm when set DER DE thresholds are exceeded 2 ALARM LED for alarming 3 BAT LED for On Off state...

Страница 16: ...ighlighted option of the MENU 4 MODE BACK OK open the list of Spectroscopic Radiation Monitor 1403 operation modes Exit or return to the previous operation mode or option Directional pad keys 5 UP 6 D...

Страница 17: ...Monitor 1403 switches off 1 2 Figure 6 3 BDAB enables the following operation modes measurement of radiation flux density measurement of radiation flux density search for radiation sources program op...

Страница 18: ...ect BDAB to Spectroscopic Radiation Monitor 1403 and enter the indication mode of BDAB operation modes To do it select the Detector BDAB line and press SELECT or ENTER key on Spectroscopic Radiation M...

Страница 19: ...c Radiation Monitor 1403 When statistical error exceeds 10 the Spectroscopic Radiation Monitor 1403 S LCD will display a corresponding message Figure 6 6 4 If current measurement error is sufficient t...

Страница 20: ...tor BDAB line and press SELECT or ENTER key on Spectroscopic Radiation Monitor 1403 Operation sequence in this mode is as follows 1 select the measurement mode of radiation flux density Measurement Mo...

Страница 21: ...r installation 8 press OK 9 Spectroscopic Radiation Monitor 1403 s LCD will indicate continuously measured flux density values of radiation in min 1 cm2 Figure 6 7 5 User can read the measured value o...

Страница 22: ...sources Figure 6 8 1 or radiation Figure 6 8 2 BDAB with Spectroscopic Radiation Monitor 1403 can as well be used to search for radiation sources But this mode is recommended when the count rate excee...

Страница 23: ...witch to the search mode automatically set detection threshold Thresholds 6 3 BDAB settings Select Detector BDAB line Figure 6 9 1 in the Spectroscopic Radiation Monitor 1403 s menu Instrument Setting...

Страница 24: ...When Display and Control Unit 1403 is switched on BDAB is energized automatically At that the POWER LED will light on the front panel of BDAB Figure 4 1 position 4 1 color LCD 3 5 89 mm 2 instrument s...

Страница 25: ...l Unit 1403 to switch off 7 2 Operation modes BDAB enables the following operation modes measurement of radiation flux density measurement of radiation flux density search for radiation sources progra...

Страница 26: ...s cursor keys Use SELECT to switch to the operation mode 1 2 3 Figure 7 4 7 2 1 Measurement mode of radiation flux density Measurement Mode To measure radiation flux density connect BDAB to Display an...

Страница 27: ...displayed graphically on the analogue scale as well Quantity of the lighting scale segments corresponds to the value of measured radiation flux density relative to the set threshold level When set thr...

Страница 28: ...r is 10 or less Current value of count rate is compared to the operation threshold calculated in the calibration mode If current value of count rate exceeds the threshold value then light sound audio...

Страница 29: ...is given in Table 10 1 Table 10 1 Possible problem Possible reasons Troubleshooting Green ALFA or BETA LED doesn t light when BDAB is being connected to Spectroscopic Radiation Monitor PM1403 Display...