PDC 2000/3000 Repair Manual
Parts Replacement
92
Power Supply/Strobe Board Installation
To install the power supply/strobe board, reverse the removal procedures.
Note:
Before installing the top cover, be sure there is protective tape between the optical
module and the lens mounting ring (Figure 5-10A); there must also be tape securing the
optical flex (Figure 5-10B) in place. Finally, be certain there is a foam pad on top of the
flash capacitor (Figure 5-10C).
Figure 5-10. Protective tape and foam block location
A
C
B
Foam block on
flash capacitor
Tape securing
optical flex
Tape between optical