57
PDC 2000/3000 Repair Manual
Testing & Adjustment
Big Hose
Notes:
• This VI only runs on LabView version 3.1.
• This program is used to reset the camera after updating a 40MB hard drive to a
60MB hard drive.
Required Test Equipment and Tools
• Mac Centris 650 Computer or equivalent
• PDC 2000 Switching Power Supply
• Camera SCSI Cable
• Camera Test Fixture (Nest)
Equipment Setup (Figure 3-13)
1. Place the camera onto the test fixture (camera nest).
2. Connect the camera SCSI cable from the host computer SCSI connector to the camera
SCSI connector.
3. Connect the switching power supply cable to the camera’s external power connector.
4. If applicable, set the camera’s SCSI ID to 4.
5. If applicable, replace camera lens with an 11mm lens.
Note:
11mm lens is standard. Some camera’s come in for repair with the
optional 17mm lens attached.
For testing purposes the standard 11mm lens must be used.
6. Turn on the test equipment as follows:
• Mac centris 650 Computer On/Off (0/1) switch to On (1).
• Turn on the camera.