24
PDC 2000/3000 Repair Manual
Testing&Adjustment
Equipment Setup (Figures 3-2 through 3-6)
Note: Figures 3-2 through 3-6 shows the equipment setup for the ambient, strobe and
color/focus parts of the calibration procedure.
1. Place the camera onto the test fixture (camera nest).
2. Connect the camera SCSI cable from the host computer SCSI connector to the camera
SCSI connector.
3. Connect the switching power supply cable to the camera’s external power connector.
4. If applicable, set the camera’s SCSI ID to 4.
5. If applicable, replace camera lens with an 11mm lens.
Note:
11mm lens is standard. Some camera’s come in for repair with the
optional 17mm lens attached.
For testing purposes the standard 11mm lens must be used.
6. Turn on the test equipment as follows:
• Power Computing PC On/Off (0/1) switch to On (1).
• Keithly 485 AutoRanging Picoammeter On/Off pushbutton to On. Adjust to ????.
• Model B Light Source Power On/Off rocker switch to On.
Note:
Allow the Model B Light Source to warm up for approximately
five (5) minutes before use.
• Turn on the camera.