ELECTRICAL WIRING

If  you  lack  the  necessary  skills  required  to  properly  install  the 

electrical  wiring  to  this  water  heater,  do  not  proceed  but  have  a 

qualified  electrician  perform  the  installation.  Refer  to  the  Power 

Supply section on Page 18 for additional requirements.
When making the electrical connections, always make sure:

• 

The voltage and frequency must correspond to that specified 

on the water heater data plate on the front of the water heater.

• 

The electrical supply has the proper overload fuse or breaker 

protection. The heater draws less than 7 amps.

• 

Wire sizes, connections and conduits comply with all applicable 

codes.

• 

The water heater and electrical supply are properly grounded.

• 

This water heater must be “hard-wired” do not use an ex

tension 

cord to supply electrical power to this water heater.

NOTE: 

The wiring diagram can be found in Figure 49 on page 57.  

Always  reference  the  wiring  diagram(s)  for  the  correct  electrical 

connections. 
When installing the electrical wiring to the water heater:

1. 

Shut off the power at the electrical service box.

2. 

Loosen the screws securing the access panel to the electrical 

compartment.  (The electrical wiring diagram for all models can 

be found on the inside of the access panel at the base of the 

water heater. Set the access panel aside. 

3. 

Connect the electrical supply to the water heater in accordance 

with local utility requirements and codes. Use only a dedicated 

electrical  circuit  containing  a  properly  sized  fuse  or  circuit 

breaker. Maximum overload protection should not exceed 15 

amperes.

4. 

Connect this circuit (directly from the electrical service box) to 

an electrical disconnect switch. 

5. 

Ground the water heater by connecting the electrical service 

ground wire to the green ground wire (provided).

NOTE:

  The  power  supply  to  this  water  heater  must  be  properly 

polarized, [120 volts from the hot lead (black) to ground and 0 volts 

from the neutral lead (white) to ground] otherwise, the unit will not 

operate.
6. 

After  making  all  electrical  connections,  completely  fill  the 

tank with water and check all connections for leaks. Open the 

nearest hot water faucet and let it run for 3 minutes to purge the 

water lines of air and sediment and to ensure complete filling 

of the tank.  The electrical power may then be turned on. See 

Page 44 for the complete Start Up instructions. 

ENABLE/DISABLE CIRCUIT 

(For Building Management Systems)

The  water  heaters  covered  in  this  manual  are  equipped  with 

an  enable/disable  circuit  for  use  with  field  supplied  external 

supervisory controls such as time clocks or Building Management 

Systems.  The  enable/disable  circuit  may  be  used  to  disable 

heating operation during periods when the building is unoccupied 

or there is no demand for hotwater.
To  use  the  enable/disable  circuit  it  must  first  be  activated  by 

selecting the “Use External Enable” from the UIM. Field supplied 

wiring is then installed between the water heater’s CCB and a 

set  of  “dry  contacts”  (no  voltage  or  load)  on  the  field  supplied 

external control.

NOTE: 

The water heater’s enable/disable circuit is a switching 

circuit only: Do not apply external voltage or connect any load 

(IE: relay coil) to this circuit. This will damage the CCB circuit 

board and is not covered under the limited warranty.

CONNECTING AN EXTERNAL SUPERVISORY CONTROL

The enable/disable circuit is accessed from the CCB’s J17 plug 

inside the CCB enclosure; see Figure 3 on page 12 to locate the 

CCB enclosure and Figure 48 on page 56 for the CCB layout. 
Install field wiring to the enable/disable circuit:

1. 

Turn  off  power  at  the  water  heater’s  enable/disable  switch 

and the breaker that supplies power to the water heater.

2. 

Locate the CCB enclosure.

3. 

Carefully  remove  the  Temperature  Probe  connectors  and 

CCB enclosure cover.

4. 

Locate pins 1 and 2 on the CCB J17 plug. See

 Figure 48 on 

page 56.

5. 

Connect the two field supplied control wires to pins 1 and 2 

on the CCB J17 plug. 

6. 

Thread the control wires out of the CCB enclosure with the 

other wiring and carefully replace the CCB enclosure cover. 

Ensure all wiring is routed through the intended area provided 

for strain relief. Ensure no wiring is being pinched.

7. 

Reinstall the CCB enclosure cover.

8. 

Route  the  control  wires  inside  the  junction  box  on  the  top 

of the water heater; see Figure 3 on page 12 to locate the 

junction box. Use an available knock-out to route the wires 

inside the junction box.

9. 

Install  field  supplied  control  wiring  and  conduit  as  required 

by  national  and  local  codes  between  the  water  heater’s 

junction  box  and  the  external  supervisory  control.  Connect 

the wiring from the external control to the control wires inside 

the junction box using wire nuts and electrical tape.

10. 

Connect  the  control  wiring  to  a  set  of  dry  contacts  on  the 

external control. Follow the control manufacturer’s instructions 

for making connections.

11. 

Restore power to the water heater.

12. 

From  the  water  heaters  UIM  “Heater  Information  Screen” 

select    “Use  External  Enable”  and  change  to  “Yes”.  See 

Figure 3 on page 12 to locate the UIM.

NOTE: 

Whenever  the  external  control  opens  the  set  of  dry 

contacts  used,  water  heating  operation  will  be  disabled. 

Whenever  the  external  control  closes  the  set  of  dry  contacts 

used, water heating operation will be enabled. A diagonal line and 

circle appears over the thermometer icon on the UIM when water 

heating operation is disabled. See the Status Icons descriptions 

in Table 12 on page 37.

NOTE:

  Ensure  the  water  heater  is  protected  from  freezing 

temperatures when water heating operation is disabled. Damage 

to  the  water  heater  caused  by  freezing  temperatures  is  not 

covered under the limited warranty.

WATER LINE CONNECTIONS

The water piping installation must conform to these instructions and 

to  all  local  and  national  code  authority  having  jurisdiction.  Good 

practice requires that all heavy piping be supported.
Read and observe all requirements in the following sections before 

installation of the water piping begins:

1.  Mixing Valves on page 18.

2. 

Dishwashing Machines on page 19.

3.  Temperature-Pressure Relief Valve on page 20.

4. 

Closed Systems and Thermal Expansion on page 19.

WATER PIPING DIAGRAMS

This  manual  provides  detailed  water  piping  diagrams  for  typical 

methods of application for the water heaters, see Piping Diagrams 

beginning on Page 59.

The water heater may be installed by itself, or with a separate storage 

tank. When used with a separate storage tank, the circulation may 

be  either  by  gravity  or  by  means  of  a  circulating  pump.  When  a 

Содержание BSS

Страница 1: ...tly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Страница 2: ...take Moisture Protection 25 Horizontal Vent Terminal Installation 25 Vertical Vent Terminal Installation 26 Termination Clearances Sidewall Direct Vent 27 Direct Vent Installation Diagrams 28 Concentr...

Страница 3: ...ot follow the safety message and how to avoid the risk of injury DANGER WARNING CAUTION CAUTION DANGER indicates an imminently hazardous situation which if not avoided will result in injury or death T...

Страница 4: ...Explosion Hazard Overheated water can cause water tank explosion Properly sized Temperature Pressure Relief Valve must be installed in the opening provided Verify the power to the water heater is tur...

Страница 5: ...5 GENERAL SAFETY INFORMATION...

Страница 6: ...nderstand instruction manual Breathing Hazard Carbon Monoxide Gas Property Damage Hazard All water heaters eventually leak Do not install without adequate drainage CAUTION Fire and Explosion Hazard Le...

Страница 7: ...tally vented gas fueled heating appliance or equipment The sign should read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The s...

Страница 8: ...These diagrams will serve to provide the installer with a reference It is essential that all venting water piping gas piping and wiring be installed as shown Particular attention should be given to th...

Страница 9: ...8 1 2 22 15 3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 cm 123 19 55 88 40 102 87 104 14 16 19 13 97 16 82 50 130 Inches 62 3 8 22 15 3 4 54 1 2 55 6 3 8 5 1 2 6 5 8 cm 165 7 55 88 40 138 43 139 7 16 19 13 97 16...

Страница 10: ...pressure must be maintained under both load and no load dynamic and static conditions Table 3 RECOVERY CAPACITIES Input Recovery Capacities Rating Btu hr Rating kW Temp Rise F 30 40 50 60 70 80 90 100...

Страница 11: ...at the bottom of heater behind the Access Doors 1 30 11 15 2 3 23 34 33 CAUTION HARNESS HAS 120 VAC IN OPERATION See Venting Installation and Condensate Piping for more information Figure 2 34 GALLON...

Страница 12: ...ation 50 GALLON UNIT FEATURES AND COMPONENTS CONT Figure 3 50 GALLON UNIT This is a view of the area at the bottom of heater behind the Access Doors 1 2 3 15 32 27 33 29 32 24 26 20 19 12 11 25 13 28...

Страница 13: ...ndensate Drain Outlet 13 Enable Disable Switch 14 Hot Water Outlet 15 Gas Supply 16 Main Manual Gas Shutoff Valve 17 Union 18 Inlet Water Shutoff Valve 19 Cold Water Inlet 20 T P Relief Valve 21 Ratin...

Страница 14: ...pressure switch that requires an increase in negative pressure to change the electrical contacts from normally closed to open The switch is connected to the pressure tap on the PVC pipe connected to...

Страница 15: ...ater heater close to a 120 VAC power supply See Power Supply on Page 18 for requirements 8 Locate the water heater where an adequate supply of fresh air for combustion and ventilation can be obtained...

Страница 16: ...ter heater Do not cover the outer door thermostat or temperature pressure relief valve Do not cover the instruction manual Keep it on the side of the water heater or nearby for future reference Doobta...

Страница 17: ...d at or above the input Btu hr rating of the water heater they supply 2 Supply gas regulators shall have inlet and outlet connections not less than the minimum supply gas line size for the water heate...

Страница 18: ...4 Water Temperature F C Time for 1st Degree Burn Less Severe Burns Time for Permanent Burns 2nd 3rd Degree Most Severe Burns 110 43 3 normal shower temp 116 46 7 pain threshold 116 46 7 35 minutes 45...

Страница 19: ...ed in the cold water supply line an expansion tank must be installed between the check valve and the water heater s cold water inlet Set storage tank temperature five degrees lower than the water heat...

Страница 20: ...ature Pressure Relief Valve on the water heater each remote storage tank that may be installed and piped to a water heating appliance must also have its own properly sized rated and approved Temperatu...

Страница 21: ...the building In cold climates it is recommended that the discharge pipe be terminated at an adequate drain inside the building Shall not have any valve or other obstruction between the temperature pr...

Страница 22: ...bustion air intake and the exhaust vent terminal Refer to Horizontal Vent Terminal Installation on Page 25 and Vertical Vent Terminal Installation on Page 26 GENERAL VENTING INSTRUCTIONS The following...

Страница 23: ...e personal injury death or substantial property damage Installations must comply with applicable national state and local codes For Canadian installation Polypropylene vent must be listed as a ULC S63...

Страница 24: ...000 ft 610 m to 7 700 ft 2 347 m IMPORTANT Do not use vent elbows in this vent pipe installation See Figure 12 90 Short Sweep Elbow 90 Long Sweep Elbow 45 Sweep Elbow Correct Fittings Incorrect Fittin...

Страница 25: ...hat it vents through the roof please refer to Vertical Vent Terminal Installation on Page 26 1 A f t e r t h e p o i n t s o f t e r m i n a t i o n h a v e b e e n determined see Vent Pipe Terminatio...

Страница 26: ...nings above anticipated snow levels FLAT ROOF INSTALLATION On flat roof installations the air intake and the exhaust vent terminations must be a minimum of 24 inches 60 cm above any parapet vertical w...

Страница 27: ...ir supply inlet into building or combustion air inlet to any other appliance 6 in 15 cm for appliances 10 000 Btuh 3 kW 12 in 30 cm for appliances 10 000 Btuh 3 kW and 100 000 Btuh 30 kW 36 in 91 cm f...

Страница 28: ...uations See the section on Direct Vent Air Intake Moisture Protection on page 25 Figure 24 SIDEWALL VENT INSTALLATION ALL MODELS See Note 3 See Note 3 Drain Pan Piped To Adequate Drain See Note 1 See...

Страница 29: ...t of a qualified installer or qualified service technician see Page 8 All precautions in the literature on tags and labels attached to the unit must be observed Follow all safety codes Wear safety gla...

Страница 30: ...ARIS UNITS 175 000 199 000 BTU HR MODELS When using two water heaters with inputs of 175 000 BTH HR or above install vent terminations using either Method A or Method B below Figure 33 When using thre...

Страница 31: ...pany will have to install a properly sized gas meter Make sure the gas supplied is the same type listed on the water heaters rating label The gas piping must be installed according to all local and st...

Страница 32: ...y of pipe in thousands of BTU per hour of undiluted liquefied petroleum gases at 11 inches water column pressure Based on a Pressure Drop of 0 5 Inch Water Column Additional tables are available in th...

Страница 33: ...ay coil to this circuit This will damage the CCB circuit board and is not covered under the limited warranty CONNECTING AN EXTERNAL SUPERVISORY CONTROL The enable disable circuit is accessed from the...

Страница 34: ...or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot wat...

Страница 35: ...120 F Status Heating MENU HELP GAS OFF O N Figure 38 HIGH TEMPERATURE LIMIT CONTROL ECO This water heater is equipped with an ECO energy cut out non adjustable high temperature limit switch The ECO i...

Страница 36: ...ion of the various operational states The Desktop screen also displays animated Status Icons to convey operational information see Table 12 on Page 37 for descriptions of the Status Icons OVERVIEW The...

Страница 37: ...control system or when the Enable Disable switch located at the base of the water heater is in disable position The Combustion Blower is being energized The Spark Igniter is being energized See Spark...

Страница 38: ...ot reset the control system if the condition that caused the Fault has not been corrected Heating Disabled The heating is disabled by the Enable Disable switch located at the base of the water heater...

Страница 39: ...will be displayed Tank Temperature 71 F Operating Setpoint 120 F Status Standby HELP MANUFACTURER MODEL INFORMATION MENU The Main Menu is where all control system menus are listed see Table 14 on page...

Страница 40: ...fferential Adjustment on page 39 Temperatures HELP BACK Operating Setpoint 120 F Differential 8 F Tank Temperature 120 F Tank Probe Offset 0 F HEATER STATUS MENU DESCRIPTION ACTION DISPLAY Press Heate...

Страница 41: ...ersion Software version for user interface module Use External Enable Enables Disables the external enable circuit External Enable Status Displays whether or not the external enable circuit has been a...

Страница 42: ...last nine 9 Fault andAlert messages with a time stamp The newest event will replace the oldest Press the Fault to view details for each Fault or Alert message stored Fault History HELP BACK 1 Upper T...

Страница 43: ...to Yes and press ACCEPT to save the new setting NOTE The Access Code at the bottom of the Service Contact Information screen is for manufacturing engineering purposes only There are no user settings...

Страница 44: ...Sequence of Operation See the Sequence of Operation Flow Chart on page 49 Ensure the water heater is properly grounded Flame sensing requires an adequate earth ground If the water heater is not proper...

Страница 45: ...42 On the water heaters covered by this manual there are test ports for supply and manifold gas pressure readings on the gas control valve Using a small flat tip pocket screw driver open the needle v...

Страница 46: ...t a t s o m r e h t e h t t e S o t s e t u n i m 5 e v i f t i a W s a g y n a t u o r a e l c s a g l l e m s n e h t u o y f I n i B w o l l o F P O T S u o y f I l e b a l s i h t n o e v o b a n...

Страница 47: ...The display CCB and other electrical components will still be energized and the display will read Water Heating Disabled 3 Close Main Gas Shutoff Valve see Figure 37 on page 31 GAS INPUT RATE The gas...

Страница 48: ...represents some of the most critical installation requirements that when overlooked often result in operational problems down time and needless parts replacement This is not a complete list Before pe...

Страница 49: ...setting a heating cycle is activated Igniter is energized 24 V Gas Control Valve is energized gas flows to Main Burner 24 V Gas Control Valve de energized 24 V Gas Control Valve de energized Is flame...

Страница 50: ...e to have the complete water heater Model Number Serial Number and Series Number available This information can be found on the rating plate affixed to the water heater For more information or technic...

Страница 51: ...l continue to lock out DIAGNOSTIC CHECKS Turn off power to the water heater before performing any service Electrical Shock Hazard Label all wires prior to disconnecting when performing service Wiring...

Страница 52: ...continuity when the blower is off and closed shorted when the blower is on Replace the switch if necessary ADVANCED BACK 0 days 0 hrs 0 mins ago Error Code A7 1201 Blocked Air Intake Restriction in ai...

Страница 53: ...the valve being slightly opened Not shown in Figure 46 F The drain valve may be leaking at the tank fitting Not shown in Figure 46 G Leakage from recirculation plug or pipe connection Not shown in Fig...

Страница 54: ...n the hose clamp at the adaptor rubber boot and slide the plastic pipe out and away from the adaptor rubber boot See Figure 14 in Integrated Filter Installation Remove the adaptor rubber boot containi...

Страница 55: ...ter heater drain valve and terminate it to an adequate drain 7 Open the water heater drain valve and allow all the water to drain from the storage tank 8 Close the water heater drain valve when all wa...

Страница 56: ...CONTROL BOARD LAYOUT 11 12 1 J16 J5 J3 J13 J4 J17 J10 J9 J14 J15 J1 J6 J12 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 6 6 6 6 6 6 7 7 8 8...

Страница 57: ...iolet CCB J3 5V Data Data D gnd SDA data SCL data Write protect 5V Dgnd CCB J12 2 Red 3 Green 4 White Brown 5 White Blue 6 White Orange Key Gas Valve L1 Neutral Protective Earth MAIN INPUT 3 CIRCUIT B...

Страница 58: ...POWER WITH APPLIANCE AS THIS MAY CAUSE ELECTRICAL LINE NOISE AND LEAD TO ERRATIC CONTROL SYSTEM OPERATION Figure 50 CIRCULATING PUMP WIRING DIAGRAM DISHWASHER LOOP WITH TOGGLE SWITCH FIELD SUPPLIED TE...

Страница 59: ...s Mixing Valve Metal Drain Pan 6 15 2cm Air Gap Max Adequate Drain set to 120 F 48 8 C or lower Mixing Valve Figure 52 TYPICAL ONE TEMPERATURE SYSTEM PIPING INSTALLATION All Models Figure 53 SAMPLE MI...

Страница 60: ...ixing Valve Manual Shut Off Valve Typ Mixing Valve 180 F Max Figure 54 AIR HANDLER PIPING INSTALLATION All Models Figure 55 POLARIS WITH AUXILLARY STORAGE TANK One or Two Temperature System With or Wi...

Страница 61: ...61 NOTES...

Страница 62: ...62 NOTES...

Страница 63: ...For Tech Support please call PGC models 1 800 456 9805 SPC models 1 800 365 0024 BSS BTS models 1 800 527 1953 Copyright 2016 A O Smith Corporation All rights reserved...

Отзывы: