Effective Utilization of Drives

Using RAID 0 only is a cost effective way to increase performance by allowing data to be

read and written faster. However, RAID 0 increases the risk of losing data as there is no

protection mechanism employed. Mirroring or RAID 1 is used to protect a user from los-

ing data from a single drive failing, but 50% of the capacity is lost to the mirrored copy.

RAID 3 provides the maximum performance and protection by using only a single drive to

protect several data striped data drives. RAID 3 provides the benefits of striped perform-

ance and protection using an on-the-fly protection engine. PNY highly recommends using

the RAID 3 configuration to fully protect all data stored on the array from a single drive

failure, especially digital camera images, downloaded music files or captured video files

that may not be backed up to another location of media.

Supported RAID Configurations

The S-CURE™ card supports multiple array configurations for maximum flexibility. Each

array may be used either as an additional storage drive in your system or as the boot

drive.

An array consists of multiple disks, but appears to the host as a single large drive. For

example, if you have three ATA 100/133 (UDMA 5 mode) drives configured in a RAID 3

configuration, each of capacity 200 Gigabytes, the host will see a large single 400

Gigabyte drive (two for data and one for protection, the latter being invisible to the user).

Each RAID 3 drive will be mapped by the host as single disk number (e.g. Disk 0, Disk

1).

Supported RAID Configurations

9

PNY Storage Manager  

The PNY Storage Manager application provides a convenient and easy to use Windows 

interface that supports monitoring, status checking, creation, deletion, rebuild and

advanced options for your S-CURE™ card. 

Install/Un-install

Insert the PNY Installation CD into the system’s CD-ROM or DVD-ROM drive. The instal-

lation should auto start. If not, from the Start menu, navigate via the Run menu to the

setup.exe program on the CD and run setup.exe. Un-install of the application can be per-

formed by re-running setup.exe or re-inserting the installation CD and selecting the

“remove” option.

Use the default options to install the application and then reboot the system.

The application auto loads after a Windows restart and log-on by the user.  It can also be

run by navigating to the Start Menu/Programs/SyncRAID Utility directory and selecting

the ”PNY Storage Manager” application icon or by clicking on the desktop shortcut 

created during CD auto installation.

Storage Manager Wizard

The PNY Storage Manager includes a wizard that will detect when you attach new drives

to your storage processing card, and will automatically recommend configurations for you.

This wizard can be cancelled at any time. See ‘creating your array’ for more detail on how

to use the wizard.

10

Содержание S-Cure

Страница 1: ......

Страница 2: ...d enables a new class of multi media streaming and acceleration using ordinary Serial ATA disk drives The S CURE card uses a completely driverless design so that it can natively operate within standard Windows XP 2000 2003 environments The S CURE card s striped parity RAID 3 mode provides the highest performance protected RAID mode in the industry providing RAID 0 performance with RAID 5 class par...

Страница 3: ...s process may take longer depending on other peripherals installed i Open the PC case following the appropriate guidelines provided by your PC or PC case vendor ii Ensure that there is adequate cooling and power for your hard drives A drive cage with additional cooling fans is recommended iii Plug the S CURE card into an available PCI slot and secure the card bracket to the PC case iv Connect the ...

Страница 4: ...ed Step 2 Auto Configuration After you attach the hard drives and first power up the computer The Storage BIOS will automatically recognize the data drive and configure it so it can be used PNY 5 Step 2 Install Storage Manager Insert the Installation CD into your CD tray The installer should auto launch Follow the prompts to install the Storage Manager The installer will then prompt you to restart...

Страница 5: ...ance striping only Risk of data loss increases linearly with the number of drives striped The user sees 100 of the sum of all the drive capacities added together RAID 1 Used to protect a single drive by copying all data simultaneously to a mirror drive The user sees only the capacity of one drive RAID 3 Used to protect a performance stripe from drive failure Adding an additional drive of equivalen...

Страница 6: ...t will see a large single 400 Gigabyte drive two for data and one for protection the latter being invisible to the user Each RAID 3 drive will be mapped by the host as single disk number e g Disk 0 Disk 1 Supported RAID Configurations 9 PNY Storage Manager The PNY Storage Manager application provides a convenient and easy to use Windows interface that supports monitoring status checking creation d...

Страница 7: ...mply select individual un configured drives drives marked with a yellow exclamation sign using a left mouse click while holding the CTRL key If all drives are being assigned to a single array simply select the top drive and while holding the SHIFT key select the bottom drive which results in all the drives being selected The types of RAID modes available with the selected drives will become highli...

Страница 8: ...grate dialogue At the bottom of the window there is a box for Partition Stretching Options If you select Automatically expand partition the PNY Storage Manager will stretch the last logical disk on the array to include your new space If this option is available we recommend you press yes If this option is not available or you choose not to use it you will need to go to the windows Disk Manager to ...

Страница 9: ...utility one of the drives will have an by it 3 When the PNY Storage Manager application is running a A pop up window will indicate a drive failure b If the email notification is enabled in Management menu An email will be issued indicating the failure c One of the drives will have a red X through it 15 To replace and rebuild a failed drive perform the following steps 1 Determine which array and dr...

Страница 10: ...ant to delay the rebuild for a while The pause button changes to a Resume button to restart the process b Abort aborts the rebuild process and resets back to the unprotected failed drive state for restart or total reconfiguration 17 c Priority slider dictates the level of priority the S CURE Data Protection card gives to the rebuild The slider bar may be dragged by clicking on it with the mouse an...

Страница 11: ...is does not affect the capability of the array to continue functioning when a single drive fails 19 Updating Your Firmware The PNY Storage Manager includes a utility that will automatically check for updates to your storage processing card firmware when you first install it You can also download update packages manually from the website at www S CURE com support html Please follow the directions t...

Страница 12: ... After you create the array save the configuration using option 5 Deleting an Array option 2 Use this option to delete arrays previously configured The drives will be freed up and will appear as U or un configured in the top part of the menu Interrupt 13 option 3 INT13 enable disable turns off the part of the BIOS that registers the arrays as bootable with the operating system This can resolve som...

Страница 13: ...hen configure the S CURE card and drives with these removed first If none of the arrays on the S CURE card are being used as boot devices You can disable the Int 13 option in the S CURE card BIOS to free system resources As a last resort try disabling the BIOS altogether using the Disable BIOS option in the BIOS level N configuration utility iii If there are multiple S CURE card s in the system an...

Страница 14: ...CD Rom 3 Hard Drive The Hard Drive Priority if it is available on your motherboard is a subcategory normally located near to the Boot Order that allows you to list the primary bootable hard drive Generally if the Boot Order function on a motherboard lists more than one hard drive available than it will not have a Hard Drive Priority function Because every motherboard BIOS is unique you should refe...

Страница 15: ...hipping costs when shipping from outside the United States this will include freight duty customs fees and taxes LIMITATIONS OF LIABILITY IN NO EVENT SHALL PNY BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR FAIL URE TO PERFORM UNDER THIS WARRANTY STATEMENT WHETHER DUE TO BREACH OF CONTRACT BREACH OF WARRANTY NEGLIGENCE OR OTHERWISE REGARDLE...