MPS6100 MAINTENANCE MANUAL
ORIGINAL INSTRUCTIONS
Page 23
7.0
ALARM INDEX
Alarm Description
Solution
High/Low deviation alarm
High/low deviation of
speed
a. Ensure speed of sealer within deviation limit
b. If alarm persists increase deviation limit
X20BR9300 not found
Bus module not found
a.Ensure bus module is installed and not damaged
b. Contact Plexpack Support for help
X20CM8281 in slot 2 not
found
Mixed I/O module not
found in slot 2
a. Ensure I/O module is installed in the correct
slot and not damaged
b. Contact Plexpack Support for help
X20DO2633 in slot 6 not
found
TRIAC module not
found in slot 6
a. Ensure TRIAC module is installed in the
correct slot and not damaged
b. Contact Plexpack Support for help
X20CM8281 in slot 3 not
found
Mixed I/O module not
found in slot 3
a. Ensure I/O module is installed in the correct
slot and not damaged
b. Contact Plexpack Support for help
X20CM8281 in slot 4 not
found
Mixed I/O module not
found in slot 4
a. Ensure I/O module is installed in the correct
slot and not damaged
b. Contact Plexpack Support for help
X20AT2402 not found
Thermocouple module
not found
a. Ensure thermocouple module is installed and
not damaged
b. Contact Plexpack Support for help
X20DO2633 in slot 7 not
found
TRIAC module not
found in slot 7
a. Ensure TRIAC module is installed in the
correct slot and not damaged
b. Contact Plexpack Support for help
E-STOP E-stop
has been engaged
a. Disengage e-stop by pulling and turning
clockwise simaltaneously
b. Press the "Start" icon to resume operation
X20BT9400 not found
Transmitter module not
found
a. Ensure transmitter module is installed and not
damaged
b. Contact Plexpack Support for help
X20DO2633 not found
TRIAC module not
found
a. Ensure TRIAC module is installed and not
damaged
b. Contact Plexpack Support for help
X20AT2402 T/C channel1-
below lower limit
Zone 1 below lower temp
lower limit
a. Allow sealer to heat up zone 1 to set value
X20AT2402 T/C channel1-
above upper limit
Zone 1 below above
temp upper limit
a. Allow sealer to cool down zone 1 to set value
X20AT2402 T/C channel1-
wire break
Zone 1 thermocouple
wire broken
a. Replace thermocouple in zone 1
X20AT2402 T/C channel2-
below lower limit
Zone 2 below lower temp
lower limit
a. Allow sealer to heat up zone 2 to set value
Содержание MPS6100
Страница 6: ...MPS6100 ORIGINAL Page vi ISO SAFETY SYMBOLS LOCATION...
Страница 7: ...MPS6100 OPERATION MANUAL ORIGINAL Page x MPS6100 OPERATION MANUAL...
Страница 27: ...MPS6100 MAINTENANCE MANUAL ORIGINAL Page xii MPS6100 MAINTENANCE MANUAL...
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 61: ...STYLE A VERTICAL R L STYLE B VERTICAL L R STYLE C HORIZONTAL R L STYLE D HORIZONAL L R W H D W D H...