MPS6100 MAINTENANCE MANUAL
ORIGINAL INSTRUCTIONS
Page 13
4.0
MAINTENANCE
When performing maintenance procedures it is a good rule of thumb to inspect the
sealing bars for built up molten plastic which can eventually become a fire hazard. To
maintain consistent sealing inspect the bars for scratches or dents and if they are present
replace the sealing bars.
4.1
REPLACING TEFLON BANDS
Plexpack Teflon bands are available on a 24-hour turn-around basis. Contact your
dealer or the Plexpack service group at +1-416-291-8085
1)
It is necessary to follow the lockout procedure 3.1, and be aware of section 3.2 which
states the cooling times of the sealing bars before continuing.
CAUTION: The sealing bars are extremely hot when machine is running—be sure to
allow bars to cool to avoid personal injury.
2)
Next, you will need to lower the rails. Refer to section 3.4 for procedure.
3)
After the rails have been lowered you must remove the tension on the Teflon bands by
turning both tension knobs shown in Figure 13 counterclockwise.
4)
Once loosened, turn the quick-release handle towards the ground until it locks in place.
This will push the heating and cooling bars apart, allowing for easy removal of the
Teflon bands. See Figure 14 for handle location.
5)
Pull the stainless steel pressure plate towards you, allowing the Teflon band to be
removed from the seal section.
Содержание MPS6100
Страница 6: ...MPS6100 ORIGINAL Page vi ISO SAFETY SYMBOLS LOCATION...
Страница 7: ...MPS6100 OPERATION MANUAL ORIGINAL Page x MPS6100 OPERATION MANUAL...
Страница 27: ...MPS6100 MAINTENANCE MANUAL ORIGINAL Page xii MPS6100 MAINTENANCE MANUAL...
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 61: ...STYLE A VERTICAL R L STYLE B VERTICAL L R STYLE C HORIZONTAL R L STYLE D HORIZONAL L R W H D W D H...