PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
16
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Inverter
Fig. 6 Spacing for mounting of inverters (indications in mm)
Mount inverters as follows:
Â
Observe a minimum distance of 50 cm to the floor.
Â
Observe a minimum distance of 50 cm to the ceiling.
Â
Slide cooling element of the inverter into the mounting fixture
1
.
Â
Hold the inverter on recessed grips
5
and push up until mounting
bolts
4
drop into slotted pieces for mounting bolts
3
on both
sides.
Â
Let down the inverter.
Mounting bolts
4
are seated in the slotted pieces.
Â
Verify that minimum distances are kept (see Fig. 6).
Â
Verify that the inverter is hanging in the mounting fixture
correctly.
743
³
150
³
150
>
500
>
500
262
>
500