background image

18 

6.4.

 

Replacing the batteries 

If the batteries are inserted incorrectly, the electronics or drive may be irreparably damaged. Only replace the batteries 

when the appliance has been completely switched off. 

NOTE:

 If the appliance is equipped with a 230 VAC connection, no batteries are present in the receiver or in battery 

box. 

 

The battery are placed in battery holder. 

 

Fig. 18 

 Battery box 

 

 

Open the battery holder by unscrewing the 4 screws 

 

Fig. 19 

 Unscrewing battery box 

 

 

Replace 4 pieces of AA/LR6 Alkaline long live batteries. 

 

Fig. 20 

 Replacing battery in battery box

 

 

Close the battery holder by screwing the 4 screws back

Содержание Galaxy Burner

Страница 1: ...ND INSTALLATION MANUAL Galaxy Burner G20 G25 Natural Gas G30 G31 Propane Butane Propane Scan for other languages L3 D1 L L1 L2 D D2 H4 H L2 H1 H2 H3 H H1 H2 H3 H4 L L1 L2 L3 D D1 D2 mm 183 3 101 82 157 1150 932 109 996 350 220 320 183 3 101 82 157 2000 1782 109 1809 350 220 320 ...

Страница 2: ...ersion 14 6 OPERATING INSTRUCTIONS 15 6 1 Setting up signal code 15 6 2 Installing the control unit Wall Switch 15 6 3 Installing the battery box 17 6 4 Replacing the batteries 18 6 5 Remote control 19 6 5 1 Switch the Fire ON and OFF 19 6 5 2 Stand by mode Pilot flame 20 6 5 3 Flame height adjustment 20 6 5 4 Flame height directly to minimum position 21 6 5 5 Flame height directly to maximum posi...

Страница 3: ...ertified and qualified specialist in gas heating and electricity and should have all the qualifications required by local law Failing to comply with the above condition may result in voiding the warranty CE Declaration of conformity We hereby declare that both the design and construction of a gas heating device manufactured by Planika Sp z o o with registered office at Bydgoskich Przemysłowców 10 ...

Страница 4: ...rs in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working The Galaxy Burner fireplace was designed for decorative purposes The surface of the Galaxy Burner fireplace including the optional glass screens may get hot up to 100 degrees Celsius WARNING Parts of the device that are easy to reach ...

Страница 5: ...rm Use only approved and certified gas connection linkage Replace the linkage every 2 years Check the flexible hose at least once per month and each time the cylinder is changed If it shows signs of cracking splitting or other deterioration it shall be exchanged for new hose of the same length and of the equivalent quality Do not connect the gas cylinder directly to the appliance without regulator...

Страница 6: ... its elements weren t damaged during the transportation if they were notify the supplier Install the Galaxy Burner fireplace in the prepared housing made according to the specification The decorative stones are to be scattered evenly around the reservoir to completely cover the burner of the fireplace WARNING The stones may not cover or be placed inside the device protecting the ignition unit Fig ...

Страница 7: ... contact with hot air need to be made of non flammable materials It is not permitted to use a device which is not housed in some way Non flammable materials Ventilation grate or slot with ventilation area of minimum 150 cm2 for fireplaces length up to 1500mm and 300cm2 for fireplaces length above the 1500mm The dimensions and shape of the ventilation grid may be designed according to client specif...

Страница 8: ... contaminations from the glass guards which could burn out on the glass during operation of the Galaxy Burner in particular fingerprints Install glass guards in the corresponding slots on the appliance as shown below Fig 4 Glass guards installation Remove the glass guards only in case of damage of the glass L3 D1 L L1 L2 D D2 H4 H L2 H1 H2 H3 A A Ventilation air Water B B Surface inclination min 5...

Страница 9: ... with glass enclosure 4 4 Gas cylinder montage WARNING In case of LPG version it is crucial to manufacture a slot in the side of the housing where the insert is placed for the gas linkage and the pressure regulator Fig 6 Installation for LPG type unit ...

Страница 10: ... base of the housing The dimensions of the housing may vary to accommodate different types and dimensions of the gas cylinders however they also have to be sufficient for hassle free installation of the gas cylinder Fig 8 Housing for gas cylinder o After making sure that the device has been correctly installed acquaint yourself with the attached User s Manual o Only after acquainting yourself with...

Страница 11: ...ss Ball gas valve should be installed in an easily accessible place and have the necessary CE mark 5 2 Connection and replacement of the gas cylinder LPG version The Galaxy Burner is delivered together with an elastic gas linkage which on one end is connected to the valve of the device and on the other end to the 37mbar regulator in the twist on version ready to be connected to the gas cylinder On...

Страница 12: ...der connectors to be fastened too tightly 3 Place the quick release regulator on the valve and press it down hard If the switch is correctly turned off you will hear a characteristic click 5 When the gas flow is required turn the valve of the bottle counter clockwise 4 To let the gas flow in turn the switch into the ON position or into the flame image Table 1 Gas cylinder connection Place the gas ...

Страница 13: ...regulator or connecting nut when the bottle valve is open 4 TAKE OFF the regulator or the connecting nut with the use of a wrench or a connecting knob 3 Take off the quick release regulator by pressing the switch horizontally and simultaneously pulling the whole regulator upwards 5 REPLACE the linkage closer or cap on the empty or partially full bottle if it s not being used 4 REPLACE the tighteni...

Страница 14: ...FF position The main burner and the pilot burner need to be turned off 3 Disconnect the regulator from the gas cylinder description above 4 Loosen the metal clamp with the use of a screwdriver philips or a flat wrench 5 Move the clamp away from the stub of gas regulator 6 Take off the linkage from the stub of regulator 7 Attach a new linkage on the stub of regulator 8 Move the clamp into the stub ...

Страница 15: ...and the receiver must first learn the hand held transmitter s signal code before the first use Press the RESET button on the receiver and keep this pressed until 2 beeps are heard Release the RESET button after the second somewhat longer beep Receiver is located in grey gas box under the insert Press within 20 seconds the button small flame on the hand held transmitter until 2 short beeps are hear...

Страница 16: ... the wallswitch Fig 12 Opening the back of the wallswitch Unscrew the cable gland and disconnect the wires by pushing grey switch pull out the connection from the sealed box Fig 13 Wire connection Pull the cable through protective conduit min 2cm diameter in a way that it would be easily removable Notice that conduit will not be supplied by the producer Fig 14 Protective conduit ...

Страница 17: ... pre made holes Cover the fasteners by placing the magnesium sticker on the front of the panel Fig 16 Location of mounting holes and magnetic sticker 6 3 Installing the battery box Determinate the location for the battery box Fireplace will be equipped with 5m cable battery box with 1 5m Connect the battery box with the cable Fig 17 Battery box connection ...

Страница 18: ...TE If the appliance is equipped with a 230 VAC connection no batteries are present in the receiver or in battery box The battery are placed in battery holder Fig 18 Battery box Open the battery holder by unscrewing the 4 screws Fig 19 Unscrewing battery box Replace 4 pieces of AA LR6 Alkaline long live batteries Fig 20 Replacing battery in battery box Close the battery holder by screwing the 4 scr...

Страница 19: ...ies have a service life of approx one year We recommend you use alkaline batteries Rechargeable batteries are not permitted To replace batteries o Open the cover on the back of the remote control o Remove the batteries from the battery compartment o Place two new 1 5V batteries LR03 or AAA type as indicated in the battery compartment o Close the cover 6 5 1 Switch the Fire ON and OFF Before operat...

Страница 20: ...empting to re light it WARNING Under conditions of increased humidity rain breeze fog dew etc there may be some temporary problems with switching on the fireplace This is a normal phenomenon associated with the dampening of the ignition element Before switching on the fireplace wait until the ignition element has dried completely You can speed up this process by blowing the pilot flame with compre...

Страница 21: ...will turn to pilot flame if there is no communication between handset and receiver for a 3 hour period The fire will continue to function normally when communication is restored Receiver Overheating Powered by mains adapter The valve turns to pilot flame if the receiver temperature is higher than 176 F 80 C If batteries are installed in the receiver in this configuration the temperature must not e...

Страница 22: ...non heating months and limited use The programmed length of inactivity to activate the system is specified by the appliance manufacturer and cannot be altered in the field 6 6 Wall Switch Fig 22 Wallswitch To Turn ON Appliance Press ON OFF button until two short beeps confirm the start sequence has begun release button Once pilot ignition is confirmed there is main gas flow Standby Mode Pilot Flam...

Страница 23: ...n such a way for them to be evenly placed on the whole surface of the main burner WARNING Remember not to cover the cover which houses the ignition and the pilot flame with stones Turn on the fireplace and check the appearance of the flame once again 8 MAINTENANCE AND UPKEEP We recommend cleaning the pilot flame and the main burner unit before the device is started again after its been removed fro...

Страница 24: ...le 6 Straighten the linkage Keep the linkage away from the housing 7 Tighten the link Check for leaks Igniter Not Working 1 Ignitor wire not connected 2 Electrode misaligned on pilot burner 3 Igniter malfunction 1 Ensure pilot electrode wire is connected 2 Realign electrode and clear any surrounding debris from area 3 Replace Igniter Low efficiency cracking sounds 1 The bottle is empty 2 The nozzl...

Страница 25: ...by the first end user Product may consist of several separate parts and different parts may be covered by a different warranty periods The manufacturer gives 2 year warranty from date of purchase an insert for its smooth operation Fireplace sealing is covered by warranty for a period of 1 year from date of purchase of the device Guarantee does not cover decorative elements and glass The use of the...

Страница 26: ...nuals I hereby declare that having read the User s Manual and the Guarantee Conditions Date and legible signature of the Buyer INSTALLER Name Address Tel fax Date of commissioning I hereby declare that the gas fireplace installed by my Company has been installed in accordance with the applicable building regulations and in accordance with the guidelines contained in the Installation and User s Man...

Отзывы: