29
Name:
Indicator of MPEG stream error: PCR accuracy of one of the programs is not
within ±500 ns (ETSI TR101290 2.4)
Node: mpeg_PCR_accuracy_error
(1.3.6.1.4.1.32108.2.2.3.4.1.27)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.4 error.
Name:
Indicator of MPEG stream error: packets with transport_scrambling_control not
00
present, but section with
table_id = 0x01
present; Section with table_id other than
0x01
on PID 0x0001 (ETSI TR101290 2.6)
Node: mpeg_CAT_error
(1.3.6.1.4.1.32108.2.2.3.4.1.28)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check the results of channel MPEG stream test for ETSI TR101290 2.6 error.
Name:
Indicator of analog channel audio broadcasting disappearing.
Node: sound_error
(1.3.6.1.4.1.32108.2.2.3.4.1.29)
Parameters:
INTEGER( true(1), false(0) ), viewing only, list
Description:
Check if a channel passed the limit test by the following test criteria: analog
channel audio broadcasting is present.
Traps
Name:
Device calibration error
Node: tCalibrationError
(1.3.6.1.4.1.32108.2.2.4)
Trap number:
1
Additional
nodes
-
Description:
Sent if device calibration error is detected (usually shortly after the device is
switched on). This error can affect the accuracy of channel parameters
measurements.
Name:
Device hardware error
Node: tHardwareError
(1.3.6.1.4.1.32108.2.2.4.2)
Trap number:
1
Additional
nodes
InfoHardware
Description:
Sent if device hardware error is detected or after the device returns to normal
operation.
InfoHardware
node contains the information about the hardware error.
Example:
Trap tHardwareError (tuner error):
InfoHardware tuner\
Trap tHardwareError (return to normal operation):
InfoHardware Ok
Name:
Device temperature error
Node: tTemperatureSeverity
(1.3.6.1.4.1.32108.2.2.4.4)
Trap number:
1
Additional
nodes
Temperature, InfoTemperature
Description:
Sent if the device temperature is beyond the allowed range of -10 to +50
0
C or after
the temperature returns to the allowed range. Temperature error affects the
accuracy of level measurements.
Temperature
node shows the current
temperature value, and
InfoTemperature
contains the data about temperature
error.
Example:
Trap tTemperatureSeverity (temperature value beyond allowed range):
Temperature 60
InfoTemperature out of range!