c)
If the Analyzer and ViewRSA server are operated in the distributed network with NAT you
should set external IP-address and port of the server with the installed ViewRSA software.
IP-address and port of server should be set to be external, taking into consideration that
they will be translated with the NAT. Example of the command (ViewRSA external IP-
address – 10.0.5.101, external port – 48050):
set server 10.0.5.101:48050
d)
restart the Analyzer by the following command:
restart
Table of the used TCP/IP ports:
port
connection mode
protocol
data direction
downstream upstream
TCP CIU-003
ViewRSA
8801
PPP*
set server auto
TCP ViewRSA
CIU-003
PPP*
8801
UDP ViewRSA
CIU-003
PPP*
8801
TCP CIU-003
ViewRSA
8801
PPP*
set server IP:PPP
TCP ViewRSA
CIU-003
PPP*
8801
* PPP – port, set in the ViewRSA settings.
3.3.5. Viewing Device Information
You should perform the following procedures to view information about CIU-003:
a) make sure the Analyzer is connected to a free COM port of the PC and that the Analyzer
configuration program is started (see Section 3.3.1);
b) type the following command:
info
c) the following data will appear in the input/output window:
Device name, e.g.:
***** CIU-003 *****
;
Hardware version of the Analyzer, e.g.:
HW version: 2.12.1
;
Software version of the Analyzer, e.g.:
SW version: 12.00.00.04
;
Serial number of the Analyzer, e.g.:
Serial number: 10040001
;
MAC address of the Analyzer, e.g.:
MAC address: 00:1f:66:03:00:04
;
IP address of the Analyzer, e.g.:
IP address: 192.168.0.1
– if the IP address is set manually;
IP address: assigned by DHCP (not assigned yet)
– if the IP address is assigned by
DHCP server, but it has not been assigned yet;
IP address: assigned by DHCP (192.168.0.1)
– if the IP address is assigned by DHCP
server, and has already been assigned.
Subnet mask, for example:
Subnet mask: 255.255.255.0
(other variants of displaying are
equivalent to those of IP address);
Network gateway address, for example:
Gateway: 192.168.0.101
(other variants of displaying
are equivalent to those of IP address);
Date and time (universal), for example:
Date/time: 07.06.2010 9:30:00 UTC
;
ViewRSA server IP address and port, for example:
Server: 10.0.5.101:48050.
3.3.6. Viewing Test Data
You can perform the Analyzer self-test by following the below procedure: