17
a) make sure the Analyzer is connected to a free COM port of the PC and that the Analyzer
configuration program is started (see Section 3.3.1);
b) type the following command:
test
c) the following test data will appear in the input/output window:
Device name, e.g.:
***** CIU-003 *****
;
Calibration status, e.g.:
Calibration: Ok;
Temperature inside the Analyzer, e.g.:
Temperature: +37C Ok
;
Tuner status, e.g.:
Tuner: Ok
;
Status of the DVB-C channel demodulator, e.g.:
Demod. DVB-C: Ok
;
Status of the DVB-T channel demodulator, e.g.:
Demod. DVB-T: Ok
;
Status of the non-volatile memory, e.g.:
Memory: Ok
;
Status of the temperature sensor, e.g.:
Temp. sensor: Ok
;
Clock status, e.g.:
Clock: Ok
;
Status of the Ethernet module, e.g.:
Ethernet: Ok
;
Status of the internal data bus, e.g.:
Internal Bus: Ok
;
Error code, e.g.:
Error code: none
.
If self-test does not detect any error,
Ok
status is displayed, and if an error is detected in any of
the test parameters,
Error
is displayed.
If there is any error detected during self-test, the Analyzer should be sent to repair service to
have the defects corrected.
Temperature error means that the temperature is beyond the allowed range. Temperature error
affects the accuracy of measurements and in some cases may even lead to the Analyzer failure. In
case such error occurs, check the Analyzer operating conditions.
3.4. Operating Analyzer with ViewRSA Software
3.4.1. General Information
ViewRSA
software is intended for operating CIU-003 Signal Analyzers via the LAN. With this
software, you can perform the following procedures:
a) edit channel template of the Analyzer;
b) edit channel plan of the Analyzer;
c) edit channel limit plan;
d) view measurement results and save them to the database;
e) check measurement results against limit plans;
f) view
device
information;
g) view self-test data of the device.
This Manual describes only
ViewRSA
installation procedure. You can find more information in
the ViewRSA operating manual.
3.4.2. PC Configuration Requirements
Minimal system requirements for your PC:
a) Intel Pentium processor 3 (or higher);
b) Microsoft Windows XP/Vista operating system, Windows Server 2003/2007;