15
e) if you enter a command incorrectly,
unknown command
message will appear on the
screen.
3.3.3. Connection to LAN
You should proceed as follows to configure parameters of CIU-003 TV Signal Analyzer in the
LAN:
a) make sure the Analyzer is connected to a free COM port of the PC and that the Analyzer
configuration program is started (see Section 3.3.1);
b) set MAC address of the device (if necessary). Example:
set mac 00:1F:66:03:00:01
CAUTION
Each Analyzer has a unique MAC address assigned by the
manufacturer and usually you do not have to change it.
In case the MAC address of the Analyzer was accidentally changed, you can restore its default
value by using the following command:
set mac default
c) if IP addresses in the LAN are appointed by DHCP server, type the following command:
set ip dhcp
CAUTION
The IP address appointed by DHCP server shall be static with
unlimited lease time to provide the Analyzer communication with
ViewRSA
.
In other case, if IP addresses are assigned manually, type the following list of commands (IP
addresses are given only as an example):
set ip 192.168.0.1
- sets the IP address
set mask 255.255.255.0
- sets subnet mask
set gw 192.168.0.101
- sets the IP address of network gateway
d) restart the Analyzer by the following command:
restart
This command is equivalent to switching the Analyzer off and then on again. You should use
this command after changing any of the Analyzer parameters related to its registration in the LAN,
and also after changing the IP address of the Analyzer in DHCP-server table of addresses.
e) connect the Analyzer to the LAN via the
ETHERNET
connector. If the connection is correct,
orange indicator will flash on the connector;
f) check the Analyzer settings by viewing identification data (see Section 3.3.5);
g) if all the settings of the Analyzer are correct, you can check its communication with the LAN
by pinging its IP address with a remote PC connected to the same LAN.
3.3.4. Connection to ViewRSA
You should proceed as follows to configure ViewRSA and CIU-003 connection mode:
a)
make sure the Analyzer is connected to a free COM port of the PC and that the Analyzer
configuration program is started (see Section 3.3.1);
b)
If the Analyzer and ViewRSA server are located at the save subnetwork or in the distributed
network without NAT, type the following command:
set server auto
and follow the rule (d)