66
~
2.3.2 Ventilation and installation
DANGER!
The appliance must be installed
by a qualified
professional only
. Do not carry out the installation yourself. RISK OF
ELECTRIC SHOCK!
The safety distance between the hob and a
wall
cupboard
above must be
at least
450 mm
.
The safety distance between the hob and an
extractor hood
above must be
at
least
760 mm
.
When installing the appliance, ensure optimal heat radiation to maintain the
operating safety.
The wall and the reach of the heat radiation above the worktop must be made of
heat-resistant materials.
To avoid any damage, the sandwich layer and adhesive must resist heat.
M
INIMUM DISTANCES REQUIRED FOR PROPER VENTILATION
The hob must be ventilated properly.
The air inlet (
D
) and outlet (
E
) must
never be blocked or covered. Always keep the appliance in proper condition.
The top closing edge of the cabinet (
X
) must not be flush with the installation
opening (
1
). Install the closing edge in offset positioning (
2
) or bevel the closing
edge (
3
). S. fig. below.