1.4 Entering slave address of EPL101
A jumper is provided to configurate the address of module for serial
communication with a master device. There are 64 possible combinations
of this jumper. To connect more than 64 devices to the same network, it is
necessary to change the value of offset. . The address is given as follows:
MODULE ADDRESS = ADDRESS OFFSET + JUMPERS COMBINATION
The address offset, which is a value stored on memory of EPL101 (default
=“1”), can be modified by writing on Word SM82.
A multiplying value is assigned by the EPL101 to each of the 6 dips
(dip set to ON = 1, dip set to OFF = 0) and values are added according to
this formule:
Combination = (DIP1*32) + (DIP2*16) + (DIP3*8) + (DIP4*4) + (DIP5*2) +
(DIP6*1)
1.5 Programming the Memory-card
To program the Memory card it is necessary to have one EPL101-1AB, the
programming software PLProg and serial cable PLC to PC. Follow the
steps below:
7. Connect EPL101-1AB to power supply
8. Enter memory card on connector CO1. Make sure that pin1 of the
connector corresponds exactly to pin1 of Memory Card
9. Start PLProg and open the file which you want to download on Memory
Card.
10. Compile the project.
11. From “PLC”, select “Create memory card” and wait for the end of
programming
12. Memory is now ready for the programmino of other EPL101 (as
explained in the following paragraph).