11
No.
Name
Description
function will disconnect decoder from encoder.
Remove decoder and encoder link relationship
quickly: When encoder is routed to decoder using
PC configurator, PF-IP Touch or IP control box, hold
down the Reset button for less than five seconds,
and then release it, it reverts to the link relationship
between encoder and decoder set via the link DIP
switch. This function applies to decoder only.
3
LAN
Connect either the copper port or fiber* port to a gigabit
Ethernet switch for IP stream input, device control and
power receiving (the unit can be powered by a
PoE-enabled switch).
Default Protocol
Default IP Mode
Auto IP
IP Address
169.254.x.x
Subnet mask
255.255.0.0
Note:
1) *Connect the fiber port to the Ethernet switch using
a single-mode or multi-mode SFP module (not
included in package). The transmission distance
may vary depending on the specific SFP module
used.
2)
DO NOT connect both the copper port and fiber
port to the Ethernet switch simultaneously,
otherwise device exceptions may occur.
4
Audio Out
Connect this 3.5 mm stereo tip-ring-sleeve port to an
audio receiver such as a speaker or amplifier for
unbalanced, stereo audio signal output.
5
RS232
Use this port to perform bi-directional serial
communication and device debug functions.
When the front panel "MODE" switch is moved to
the "NORMAL" position, connect this port to a
RS232 device such as a computer to bi-directionally
communicate with a RS232 device at the IP control
box side.
When the front panel "MODE" switch is toggled to
the "DEBUG" position, connect this port to a RS232
device such as a computer for debugging
PF-IPDJ100F.
6
HDMI OUT
Connect this port to an HDMI display device.
7
IR IN
Connect this 3.5 mm tip-ring-sleeve port to an IR
receiver for IR communication with an IR emitter in the