M0158B IT | en
38
/60
Installation, use and maintenance
E2 USERS BUTTONS
FOREWORD
The METER features two buttons (RESET and CAL) which individually perform
two main functions and, together, other secondary functions.
MAIN
FUNCTIONS
PERFORMED
- for the RESET key, resetting the partial register and Reset Total
- for the CAL key, entering instrument calibration mode
SECONDARY
FUNCTIONS
Used together, the two keys permit entering configuration mode where the
desired unit of measurement can be set.
LEGEND
CALIBRATE MEANS PERFORMING ACTIONS ON THE METER KEYS.
BELOW IS THE LEGEND OF THE SYMBOLS USED TO DESCRIBE THE AC-
TIONS TO BE PERFORMED
SHORT
PRESSURE
OF CAL
KEY
CAL
LONG
PRESSURE
OF CAL
KEY
CAL
CAL
CAL
SHORT
PRESSURE
OF RESET
KEY
RESET
LONG
PRESSURE
OF RESET
KEY
RESET
RESET
RESET
F INSTALLATION
FOREWORD
K900 has a 3 inch inlet and outlet. It was designed for permanent installa-
tion on a distribution line and to this purpose, the measurement chamber is
fitted with a threaded inlet and outlet.
The two cables (each one consisting of two wires) sticking out from the
cover of the measurement chamber are to be connected to K900 remote
display.
WARNING
K900 does not have a fixed direction of flow and both inlets can be used
as inlet and outlet. It is the filter position which determines the inlet di-
rection of the fluid.
Make sure a filter with adequate filtering capacity is always fitted either
at meter inlet or at the entrance of the line on which the meter is fitted.
If solid particles enter the measurement chamber, the gears could seize.
On installations, place the meter in a position that will enable an easy
access to the batteries compartment
Содержание K900
Страница 30: ......