M0158B IT | en
50
/60
Installation, use and maintenance
L CONFIGURATION
K900 has a menu with which the user can configure the machine in accordance with his/her requirements.
The configuration menu consists of two sub-menus:
1
configuration menu for the main unit of measurement,
2
configuration menu of the number of impulses per unit of measurement that
are emitted by the Puls-Out output (in the relevant models).
To enter the configuration menu, proceed as follows:
1
wait until K900 is in Stand-by
2
press the CAL and RESET buttons at the same time and hold them down
until the word “Unit” and the previously-set unit of measurement appear on
the display (Litre/Litre in this example)
3
to move between sub-menus press the CAL button once quickly
CAL
CAL
CAL
CAL
CAL
CAL
RESET
RESET
RESET
L1
CONFIGURATION OF THE UNITS OF MEASUREMENT
The METER feature a menu with which the user can select the main measurement unit, Quarts (Qts), Pints
(Pts), Litres (Lit), Gallons (Gal); he combination of the unit of measurement of the Partial register and
that of the Totals is predefined according to the following table:
Combination no.
Unit of Measurement
Partial Register
Unit of Measurement
Totals Register
1
Litres (L)
Litres (L)
2
Gallons (Gal)
Gallons (Gal)
3
Quarts (Qts)
Gallons (Gal)
4
Pints (Pts)
Gallons (Gal)
To choose between the 4 available combinations:
1
Wait for the METER to go to Standby
2
CAL
RESET
+
Then press the CAL and RESET keys together. Keep these pressed until the
word “UNIT” appears on the screen together with the unit of measurement
set at that time (in this example Litres / Litres )
3
RESET
Every short press of the RESET key, the various combinations of the units of mea-
surements are scrolled as shown below: