57
/124
57
/60
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Translated from Italian
Q TECHNICAL SPECIFICATIONS
Measurement system
Oval gears
Resolution
(nominal)
0,070 (Litres/pulse) - 0.018 (gal/pulse)
Flow Rate
(Range)
50 ÷ 500 (Litres/minute) - 13 ÷ 132 (gal/min)
Operating pressure
(Max)
20 (Bar) - 290 (psi)
Bursting pressure
(Min)
40 (Bar) - 580 (psi)
Storage temperature
(Range)
-20 ÷ + 70 (°C) - -4 +158 (°F)
Storage humidity
(Max)
95 (% RU)
Operating temperature
(Max)
60 (°C) - 140 (°F)
Flow resistance
At 255 l/min (67.3 gal/min) with
diesel at 20°C
+/- 1.3 (Bar) - 18.8 (psi)
Viscosity
(Range)
between 2 and 5.35 cSt
Accuracy
(between 50 and 500 l/min)
+/- 0.5% of value indicated after calibration
Reproducibility
(Typical)
+/- 0,2 (%)
Screen
Liquid crystals LCD
Featuring:
- 5-figure partial
- 6-figure Reset Total plus x10 / x100
6-figure non reset Total plus x10 / x100
Battery power
2x1.5 V alkaline batteries size 1N
External Power
4 ÷ 12 Vdc
Battery life
18 ÷ 36 months
Weight
12.5 kg - 27.5 (lbs) (including batteries)
Содержание K900