I2.1 DISPLAY OF CURRENT CALIBRATION FACTOR AND
RESTORING FACTORY FACTOR
CAL
CAL
CAL
By pressing the CAL key while the appliance is in Standby,
the display page appears showing the current calibration
factor used. If no calibration has ever been performed, or
the factory setting has been restored after previous calibra-
tions, the following display page will appear:
The word “Fact” abbreviation for “factory” shows that the
factory calibration factor is being used
If, on the other hand, calibrations have been made by the
user, the display page will appear showing the currently
used calibration factor ( in our example 0,998) .
The word “user” indicates a calibration factor set by the
user is being used..
CAL
The flow chart alongside
shows the switchover
logic from one display page to
another
In this condition, the Reset
key permits switching from
User factor to Factory factor.
To confirm the choice of cali-
bration factor, quickly press
CAL while “User” or “Fact”
are displayed.
After the restart cycle, the
K400 uses the calibration
factor that has just been
confirmed
CAL
CAL
CAL
CAL
RESET
RESET
TIme OUT
ATTENTION
When the Factory Factor is confirmed, the old User factor is deleted
from the memory