SERVICE
30
L22-236 Rev. 2 (06/11)
5.4.6. Tank Assembly
1. For filter-equipped fryers apply pipe thread
compound or Teflon tape to return valve
fitting(s), Install return valve fitting(s) into rear
of tank using 1” wrench.
2. Install return valve(s) onto return valve
fitting(s), (if so equipped).
a. For split tanks, leave return valves slightly
loose so that return tubing between them
can be installed. Connect tubing loosely to
both valves.
b.
Rotate valves into position using a large
Phillips screwdriver inserted into the open port
on the return valves.
c. Tighten the return valves using 1 1/8”
wrench on return valve and 1” wrench on
tank fitting.
d. Tighten the return tubing between the
return valves, using a 1-1/16” wrench.
3. For non-filter fryers, ensure ½” plug is installed
in rear tank fitting(s).
4. For split tanks, install flue gasket on rear of
tank. Spray glue may be used to hold gasket in
place.
5. Install
flue.
WARNING! SHUT OFF APPLIANCE AND DISCONNECT ALL POWER
CONNECTIONS PRIOR TO STARTING ANY SERVICE WORK