19. Remove 2 tank to cabinet mounting screws at
rear of tank, using 5/16 hex bit.
20. Remove fry tank from cabinet.
5.4.5. Tank Disassembly
1. Remove probe clamp(s) from tank(s) using
Phillips screwdriver.
2. Remove high limit assembly(s) from tank. See
Section 5.4.2.
3. Remove drain valve(s) from tank using pipe
wrench.
4. Remove 6 burner rack mounting screws from
tank, using 5/16” hex bit. Remove burner rack
from tank(s).
5. Remove 4 screws and nuts securing flue to
tank using 5/16” hex bit and 3/8” socket or box
wrench. Remove flue from tank.
6. For filter equipped fryers, disconnect return
valve(s) from tank fitting using 1 1/8” wrench
on valve and 1” wrench on tank fitting.
7. For split tank fryers disconnect the return
tubing from one of the two return valves.
8. Remove return valve fitting, (if so equipped),
from tank using 1” wrench.
WARNING! SHUT OFF APPLIANCE AND DISCONNECT ALL POWER
CONNECTIONS PRIOR TO STARTING ANY SERVICE WORK