6. Attach flue to flue brackets using 5/16” hex bit
and 3/8” socket or box wrench to tighten
screws and nuts.
7. Clean old gasket material from burner rack
face. Install new burner gasket onto burner
rack. Spray glue may be used to hold gasket in
place.
8. Install burner rack onto tank front. Secure
burner rack to tank using 6 screws and a 5/16”
hex bit. On full tanks, leave out 2 screws in
lower right front of rack. On split tanks, leave
out 2 screws in lower center of rack. (These
screws will be installed when the high limit
bracket is installed.)
9. Apply pipe thread compound or Teflon tape
onto tank drain nipple(s).
10. Install drain valve(s) onto tank nipple(s) using
pipe wrench. On full tanks, tighten until drain
valve stem is facing right. On split tanks, drain
valve stems should face each other.
11. Insert probe(s) from top of tank through
fitting(s) in tank bottom.
12. On split tanks, install probe clamp using
Phillips screwdriver.
WARNING! SHUT OFF APPLIANCE AND DISCONNECT ALL POWER
CONNECTIONS PRIOR TO STARTING ANY SERVICE WORK