33
ELECTRICAL WIRE DIAGRAM
The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120 V, 60 Hz, 250 W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
LOCATE AND REMOVE
THE EIGHT SCREWS
OF ACCESS PANEL ON
UNDERSIDE OF UNIT
FUEL INPUT
RATING:
2.48 LB/H
(1.12 KG/H)
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
G : GREEN
S : SILVER
P
P
R
Y
Y
Y
P
K
W
W
G
W
W
W
R R
W
W
W
W
Y
Y
K
W
S
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
110-120V, 200W,
BURN POT
DRAFT FAN
110-120V, 60Hz,
1 PHASE
GROUNDED
POWER CORD
AUGER MOTOR
& FEED SYSTEM
110-120V, 60Hz,
2 RPM MOTOR
GROUND
GRILL
PROBE
GRILL PROBE
CONNECTOR
FAST-BLOW FUSE
CONTROL BOARD