PDP-507CMX
184
1
2
3
4
1
2
3
4
C
D
F
A
B
E
[QSU]: To acquire data on the audio status
[QSI]: Response format
[QCI]: Response format
Order
Data Contents
Size
Remarks
1
STX
1Byte
02hex
2
Command echo back
3Byte
QSU (fixed)
3
Main volume
3Byte
000 - 042
4
Audio mute state
1Byte
0: OFF 1: ON
5
INPUT1 sub volume
3Byte
000 - 020
6
INPUT2 sub volume
3Byte
000 - 020
7
INPUT3 sub volume
3Byte
000 - 020
8
INPUT4 sub volume
3Byte
000 - 020
9
INPUT5 sub volume
3Byte
000 - 020
10
Check sum
2Byte
11
ETX
1Byte
03hex
Order
Data Contents
Value
Length
(BYTE)
1
STX
1
0x02
2
Echo back
3
"QCI"
3
Time information
2
Time (24 hours system)
2
Minute
2
Seconds
4
Dummy data
8
All "
∗
"
5
Days
1
Days (refer to the following table)
6
Check sum
2
(CS)
7
ETX
1
0x03
[QCI]: Days
Days
(response)
Days
Sunday
"1"
"2"
Monday
Tuesday
"3"
"4"
Wednesday
"5"
Thursday
"6"
Friday
"7"
Saturday
14: Detection of existence of H
N
No H
Y
H detected
18 to 20: Each protection
operation status
0
Setting OFF
1
Setting ON (waiting)
2
Setting ON (during operation)
22: Transition of brightness by
protection operation
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
Data Arrangement
Data Length
Output Example
ECO
3 Byte
QSI
1
Type of drive sequence
3 Byte
60V
2
Standard/nonstandard
1 Byte
S
3
Type of ABL/WB tables
2 Byte
T1
4
Total value of PCN
4 Byte
0256
5
Total value of PRH
4 Byte
0256
6
Total value of PGH
4 Byte
0256
7
Total value of PBH
4 Byte
0256
8
Total value of PBR
4 Byte
0512
9
Total value of PRL
4 Byte
0512
10
Total value of PGL
4 Byte
0512
11
Total value of PBL
4 Byte
0512
12
Total value of ABL
3 Byte
128
13
Detection of V frequency
4 Byte
6002
14
Detection of existence of H
1 Byte
Y
15
Reserved
3 Byte
***
16
Obtained APL data
4 Byte
1023
17
Number of SUS pulses
4 Byte
0457
18
Result of detection of still picture
1 Byte
1
19
Result of detection of cracking in the panel
1 Byte
1
20
Result of detection for scanning protection
1 Byte
1
21
Result of detection for external protection
1 Byte
1
22
Transition of protection operation
1 Byte
0
23
Reserved
4 Byte
****
CS
2 Byte
27
If the data for the current time are fewer than two digits (0-9,) the higher-order
digit will be padded with a zero.
If the data for the current minute are fewer than two digits (0-9,) the
higher-order digit will be padded with a zero.
If the data for the current second are fewer than two digits (0-9,) the
higher-order digit will be padded with a zero.
Содержание PDP 507CMX
Страница 18: ...PDP 507CMX 18 1 2 3 4 1 2 3 4 C D F A B E 2 6 PANEL CHASSIS SECTION 1 9 2 11 4 7 7 7 7 7 3 7 10 8 7 10 7 6 5 ...
Страница 44: ...PDP 507CMX 44 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Страница 45: ...PDP 507CMX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 84: ...PDP 507CMX 84 1 2 3 4 1 2 3 4 C D F A B E 500ns div 500ns div 200ns div ...
Страница 104: ...PDP 507CMX 104 1 2 3 4 1 2 3 4 C D F A B E ...
Страница 108: ...PDP 507CMX 108 1 2 3 4 1 2 3 4 C D F A B E ...
Страница 208: ...PDP 507CMX 208 1 2 3 4 1 2 3 4 C D F A B E THC63LVD104AF K IC101 LVDS ASSY LVDS Receiver Block Diagram Pin Function ...
Страница 209: ...PDP 507CMX 209 5 6 7 8 5 6 7 8 C D F A B E MP2367DN LF IC302 DD ASSY Converter IC Block Diagram Pin Function ...
Страница 210: ...PDP 507CMX 210 1 2 3 4 1 2 3 4 C D F A B E NCP5211BDG IC303 DD ASSY Regulator IC Block Diagram Pin Function ...