Data Arrangement
Data Length
Output Example
ECO
3 Byte
QS2
1
Notification of mode shifting to STB
1 Byte
1
2
Flag for adjustment of the main unit
1 Byte
0
3
Flag for adjustment-data backup
1 Byte
0
4
"1st PD" data
1 Byte
0
5
"2nd PD" data
1 Byte
0
6
Still picture detection
1 Byte
0
7
Reserved
2 Byte
∗∗
8
Temperature data (TEMP 1)
3 Byte
128 (*1)
9
SD main data
1 Byte
0
10
SD sub data
1 Byte
0
11
Operation status induced by SD
1 Byte
0
12
Data from the hour meter
8 Byte
00000259 (*2)
13
MASK indication
1 Byte
0
CS
2 Byte
4A
1:
Notification of mode
shifting to Standby
0
Entering Standby mode
failed
1
Entering Standby mode
succeeded
2:
Adjustment of the
main unit
0
Adjustment completed
1
Adjustment not completed
3:
Adjustment-data
backup
0
With backup data
1
No data (default)
6: Still picture detection
0
Normal screen
1
Still picture
4, 5: PD data
0
No PD data
1
Not used
2
POWER
3
SCAN
4
SCN-5V
5
Y-DRV
6
Y-DCDC
7
Y-SUS
8
ADRS
9
X-DRV
A
X-DCDC
10-1: SD-Sub (SQ-IC)
0
No SD-Sub data
1
Communication error
2
Drive stop
6
Version mismatching
3
BUSY
B
X-SUS
C
Not used
D
Not used
E
Not used
F
UNKNOWN
9: SD main data
0
No SD
1
SQ-IC
2
MDU-IIC
3
RST2
4
TEMP
11:
Operation status
induced by SD
0
Normal
1
Relay-off completed
2
During warning indication
13: MASK indication
0
MASK-OFF
1
MASK-ON
Note :
(*1) : The unit scale is centigrade. The data is A/D value from the
thermal sensor.
(*2) : "00000259" of "Data from the hour meter" means
2 hours 59 minuts.
10-2: SD-Sub (IIC)
0
No SD-Sub data
1
EEPROM
2
BACKUP
3
DAC
10-3: SD-Sub (TEMP)
0
No SD-Sub data
1
TEMP1
2
Reserved
[QS2] Response format
[QIP] Response format
[QAJ] Response format
Data Arrangement
Data Length
Output Example
ECO
3 Byte
QIP
1
SERIAL
15 Byte
- - - - - - - - - - - - - - -
2
HOUR METER
8 Byte
00000000
3
TOTAL HOUR METER
8 Byte
00000000
4
PON COUNTER
8 Byte
00000000
5
TEMP1 acquisition (Temperature value)
5 Byte
+23.5(*)
6
TEMP0 acquisition (Temperature value)
5 Byte
+28.7(*)
7
MAX-TEMP1 acquisition (Temperature value)
5 Byte
+78.3(*)
8
Reserved
4 Byte
∗∗∗∗
CS
2 Byte
94
(*) : Centigrade scale
Data Arrangement
Data Length
Output Example
ECO
3 Byte
QAJ
1
V-SUS adjustment value
3 Byte
128
2
V-OFT adjustment value
3 Byte
128
3
V-RST-P adjustment value
3 Byte
128
4
Reserved
3 Byte
∗∗∗
5
XSB adjustment value
3 Byte
128
6
YSB adjustment value
3 Byte
128
7
YTG adjustment value
3 Byte
128
11
RYW adjustment value
3 Byte
128
12
R-REVICE setting value
1 Byte
0
13
G-REVICE setting value
1 Byte
0
8
YTW adjustment value
3 Byte
128
9
RSW adjustment value
3 Byte
128
10
YTB adjustment value
3 Byte
128
14
B-REVICE setting value
1 Byte
0
CS
2 Byte
B7
• For each REVICE setting value, the level set for RRL, RGL, or RBL is transmitted as one character.
Содержание PDP 507CMX
Страница 18: ...PDP 507CMX 18 1 2 3 4 1 2 3 4 C D F A B E 2 6 PANEL CHASSIS SECTION 1 9 2 11 4 7 7 7 7 7 3 7 10 8 7 10 7 6 5 ...
Страница 44: ...PDP 507CMX 44 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Страница 45: ...PDP 507CMX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 84: ...PDP 507CMX 84 1 2 3 4 1 2 3 4 C D F A B E 500ns div 500ns div 200ns div ...
Страница 104: ...PDP 507CMX 104 1 2 3 4 1 2 3 4 C D F A B E ...
Страница 108: ...PDP 507CMX 108 1 2 3 4 1 2 3 4 C D F A B E ...
Страница 208: ...PDP 507CMX 208 1 2 3 4 1 2 3 4 C D F A B E THC63LVD104AF K IC101 LVDS ASSY LVDS Receiver Block Diagram Pin Function ...
Страница 209: ...PDP 507CMX 209 5 6 7 8 5 6 7 8 C D F A B E MP2367DN LF IC302 DD ASSY Converter IC Block Diagram Pin Function ...
Страница 210: ...PDP 507CMX 210 1 2 3 4 1 2 3 4 C D F A B E NCP5211BDG IC303 DD ASSY Regulator IC Block Diagram Pin Function ...