187
6.1 Precautions
1) If the power shuts down and stays OFF for a long period of time, an internal problem has probably occurred (broken
part, etc.).
Turn OFF the main power switch on the plasma display, then wait 1 to 2 minutes and try turning the power ON again.
If the power goes OFF again, the display is probable broken.
If the display operates normal, there is no problem in continuing to use it as it is.
2) When an image (still image, telop, etc.) is shown on the screen for a long period of there is a possibility that the
image could be burned in and not be able to be removed. This should be managed by making necessary changes in
the video software, projection method, system configuration etc.
3) The following kinds of input signals could cause inferior image quality.
• Video signal that has been dubbed (copied) repeatedly
• Copyright-protected video signals
• Scrambled cable TV signals
• Signals with a sync signal and video signal that are extremely out of phase
4) The fan starts operating when the surrounding temperature is greater than 35 °C, and the fan rpm will become faster
as the temperature increases, however this is normal.
5) Screen-saver function (still image detection)
When an image having little motion such as a photograph or PC screen is displayed continuously, the brightness will
drop a little. This is because in order to protect the plasma panel, the screen-saver function detects images with little
motion ad automatically adjusts the brightness, and is not an indication that the display is broken.
Time until the screen-saver function operates:
• Normal-operation mode/menu mode: Approximate 3 minutes after the power is turned ON or after the input is
switched.
7
Self-diagnosis Function
When there is an error in the operation or connection, an error message is displayed on the screen.
After reading the contents of the error message, check the condition of the unit.
Precautions
Error Message
CAUTION
OUT OF RANGE or
CAUTION
UNSUPPORTED SIGNAL or
SIGNAL NG
WARNING
THERMAL ALERT
SHUT DOWN (
∗∗
)
WARNING
FAN FAILURE
SHUT DOWN (
∗∗
)
ERROR
INVALID KEY ENTRY
SHUT DOWN (
∗∗
)
Remedy
¶
The current signal input is not supported by the unit. Check the table of supported
input signals on pages 140 - 145 and change the output signal setting.
¶
The current signal input is not supported when FRC is set to MODE2 or MODE3.
Check the FRC settings on page 208.
¶
Turn OFF the main power.
¶
Check whether the surrounding temperature is high.
¶
If the cooling vents on the display are blocked, remove the obstacles blocking the
vents.
¶
There is a problem with the fan. Immediately turn OFF the power and contact the
Pioneer service center or dealer.
¶
An invalid operation was attempted. Check the input signals, connections and
settings.
¶
Turn the main power OFF, wait 1 or 2 minutes and turn the power ON again. If the
problem still persists, remove the power plug from the outlet and contact a Pioneer
service center or dealer.
(
∗∗
): Numbers are displayed here.
Содержание PDP-42MXE10
Страница 57: ...57 Video Card PDA 5003 PDA 5004 ...
Страница 71: ...71 Tilt Mount Unit PDK 5011 ...
Страница 83: ...83 Plasma Display Ceiling Mounting Hardware PDK 5012 ...