52
Sentinel & PimaGuard
Installation Guide
Bell 2
322
3
0
42
2
C E
1I
1I
Alarm relay
323
3
0
43
3
C E
1J
1J
Trouble relay
324
3
0
44
4
C E
1K
1K
Reversing relay
325
3
0
45
5
C E
1L
1L
Notification Appliance Ckt. # 3
326
3
0
46
6
C E
00
00
Notification Appliance Ckt. #4
327
3
0
47
7
C E
00
00
System Peripheral trouble
330
3
0
4A
A
C E
1M
1M
Polling loop open
331
3
0
4B
B
C E
1N
1N
Polling loop short
332
3
0
4C
C
C E
1O
1O
Expansion module failure
333
3
0
4D
D
C E
1P
1P
Repeater failure
334
3
0
4E
E
C E
1Q
1Q
Local printer out of paper
335
3
0
4F
F
C E
1R
1R
Local printer failure Zone Digital Comm.
336
3
0
50
0
C E
1S
1S
Exp. Module DC Loss
337
*
0
51
1
C E
00
00
Exp. Module Low Bat.
338
*
0
52
2
C E
00
00
Exp. Module Reset
339
*
0
53
3
C E
00
00
Exp. Module Tamper
341
*
0
55
5
C E
00
00
Exp. Module AC Loss
342
*
0
56
6
C E
00
00
Exp. Module self-test fail
343
*
0
57
7
C E
00
00
RF Receiver Jam Detect
344
*
0
58
8
C E
00
00
Communication trouble
350
1
0
5E
E
C E
1t
1t
Telco 1 fault
351
1
0
5F
F
C E
1u
1u
Telco 2 fault
352
1
0
60
0
C E
1v
1v
Long Range Radio xmitter fault
353
1
0
61
1
C E
1w
1w
Failure to communicate event
354
1
0
62
2
C E
1x
1x
Loss of Radio supervision
355
1
0
63
3
C E
1y
1y
Loss of central polling
356
1
0
64
4
C E
1z
1z
Communication trouble
350
3
0
5E
E
C E
1T
1T
Telco 1 fault
351
3
0
5F
F
C E
1U
1U
Telco 2 fault
352
3
0
60
0
C E
1V
1V
Long Range Radio xmitter fault
353
3
0
61
1
C E
1W
1W
Failure to communicate event
354
3
0
62
2
C E
1X
1X
Loss of Radio supervision
355
3
0
63
3
C E
1Y
1Y
Loss of central polling
356
3
0
64
4
C E
1Z
1Z
Long Range Radio VSWR problem
357
*
0
65
5
C E
00
00
Protection loop
370
1
0
72
2
C E
2a
2a
Protection loop open
371
1
0
73
3
C E
2b
2b
Protection loop short
372
1
0
74
4
C E
2c
2c
Fire trouble
373
1
0
75
5
C E
2d
2d
Protection loop
370
3
0
72
2
C E
2A
2A
Protection loop open
371
3
0
73
3
C E
2B
2B
Protection loop short
372
3
0
74
4
C E
2C
2C
Fire trouble
373
3
0
75
5
C E
2D
2D
Exit error alarm (zone)
374
1
*
76
6
C E
s*
s*
Exit error alarm (zone)
374
3
*
76
6
C E
S*
S*
Panic zone trouble
375
*
0
77
7
C E
00
00
Hold-up zone trouble
376
*
0
78
8
C E
00
00
Swinger Trouble
377
*
0
79
9
C E
00
00
Cross-zone Trouble
378
*
0
7A
A
C E
00
00
Sensor trouble
380
1
0
7C
C
C E
2e
2e
Loss of supervision - RF
381
1
0
7D
D
C E
2f
2f
Loss of supervision - RPM
382
1
0
7E
E
C E
2g
2g
Sensor tamper
383
1
0
7F
F
C E
2h
2h
RF low battery
384
1
0
80
0
C E
2i
2i
Sensor trouble
380
3
0
7C
C
C E
2E
2E
Loss of supervision - RF
381
3
0
7D
D
C E
2F
2F
Loss of supervision - RPM
382
3
0
7E
E
C E
2G
2G
Sensor tamper
383
3
0
7F
F
C E
2H
2H
RF low battery
384
3
0
80
0
C E
2I
2I
Smoke detector Hi sensitivity
385
*
0
81
1
C E
00
00
Smoke detector Low sensitivity
386
*
0
82
2
C E
00
00
Intrusion detector Hi sensitivity
387
*
0
83
3
C E
00
00
Intrusion detector Low sensitivity Zone
388
*
0
84
4
C E
00
00
Sensor self-test failure
389
*
0
85
5
C E
00
00
Sensor Watch trouble
391
*
0
87
7
C E
00
00
Drift Compensation Error
392
*
0
88
8
C E
00
00
Maintenance Alert
393
*
0
89
9
C E
00
00
Open/Close
400
1
*
90
0
C E
t*
t*
O/C by user
401
1
*
91
1
C E
u*
u*
Group O/C
402
1
*
92
2
C E
v*
v*
Open/Close
400
3
*
90
0
C E
T*
T*
O/C by user
401
3
*
91
1
C E
U*
U*
Group O/C
402
3
*
92
2
C E
V*
V*
Automatic O/C
403
1
0
93
3
C E
2j
2j
Late to O/C (Note: use 453, 454 instead )
404
1
0
94
4
C E
2k
2k
Deferred O/C (Obsolete- do not use )
405
1
0
95
5
C E
2l
2l
Automatic O/C
403
3
0
93
3
C E
2J
2J
Late to O/C (Note: use 453, 454 instead )
404
3
0
94
4
C E
2K
2K
Deferred O/C (Obsolete- do not use )
405
3
0
95
5
C E
2L
2L
Cancel
406
1
*
96
6
C E
w
w
Cancel
406
3
*
96
6
C E
W
W
Remote arm/disarm
407
1
0
97
7
C E
2m
2m
Quick arm
408
1
0
98
8
C E
2n
2n
Key switch O/C
409
1
0
99
9
C E
2o
2o
Callback request made
411
1
0
9B
B
C E
2p
2p
Successful download/access
412
1
0
9C
C
C E
2q
2q
Description
CID/PID Code
HEX2DGT
ELL
ELL IRCN
Atia* Atia Ext.*