26
Sentinel & PimaGuard
Installation Guide
be ignored.
The list itself is a text file and the values that are manually inserted into it, should be divided by any punctuation
mark or a space. The text file must carry the name FLL (not case sensitive) and the extension tells the PimaGuard
where to implement the limit list (see the next table).
The list can be changed at any time.
The blank filename is TSCFN.FLL where:
• T: filter type;
• S: source (the number of sentinels, repeaters or comm.s etc.);
• C: channel;
• F: format;
• N: filter number.
Replace the extension according to the next table. The type, Source and Filter no. must be used in every
configuration. An empty table cell means do not use this channel/format.
Examples:
S14B0.FLL
This filename tells the PimaGuard to receive transmissions only from Sentinel card #2 in Radio #1, and only
when the format in use is format no. 12 in the formats list. After that, the PimaGuard reads the content of the
file under the list limit no. and compares it to the transmission’s content: only matching values are received.
C10.FLL
This filename tells the PimaGuard to receive transmissions only from Comm. #2. After that, the PimaGuard reads
the content of the file under the list limit no. and compares it to the transmission's content: only matching values
are received.
R201.FLL
This filename tells the PimaGuard to receive transmissions only from Reapeter #3 in the repeaters list, channel
#1, filter #2.
Event
Filter the communication by the Events numbers. There are 2 filtering ranges and a limit list (see the Account
section before).
PAF, 4X2 and any other non-decimal events are converted to decimal numbers.
Date
Events outside a date range are filtered.
Days
The number of days from the day the ‘bs1’ file is created.
Time
Events outside a time range (in hours) are filtered.
Format
Filter the communication by the event format. For each Line/Radio/Channel there can be 2 filters, i.e. only the
filtered formats will be handled.
Channel
Filter events by the physical channel - Sentinel or Communication, i.e., line X, Radio X, Repeater X, COM X, etc.
For example, when viewing the monitor, you can filter events and see only those who are received through COM 1.
Type
Source
Channel
Format
Filter No.
S: Sentinel card
0-8
Line: 0-3 ; Radio: 4-5
0-9; A-V
0-1
C: COM
0-8
0-1
L: Log
0-8
0-1
R: Repeater
0-8
0-7
0-9; A-V
0-1
M: Monitor
0-8
0-1
Содержание PIMAGUARD