Captain 6 Installation Guide
13
In the “Zone responses” screen (see section 5.1.2), go to the zone that should
activate the MIC-200 and set “G” (PGM) to “+”. This will set the zone to trigger the
PGM output, to which the MIC-200 is connected, when the zone is triggered.
In the “Config 3” (see section 5.4.3) set “G” (delayed PGM) to “+”
1
. This will delay
the triggering of the PGM output, so the dialer can call the subscriber first.
2.7.2
VU-20(U)
Diagram 8.
VU-20(U) wiring diagram. The Yellow & white wires are not in use!
The VU-20(U) is a voice module that can play a recorded message over the phone,
when the alarm is set off.
The message is played instead of the synthesized siren sound and can contain, for
example, the zone name where the alarm was set off.
The trigger to the voice module can come from either the SMOKE or PGM outputs.
To program a zone to trigger the VU-20U, follow the next steps:
In the “Zone responses” screen (see section 5.1.2), go to the zone that should
trigger the VU-20U and set “G-PGM” or “F-Fire” to “+”, so the zone will trigger the
PGM/SMOKE output, to which the VU-20N will be connected, when the zone is
triggered.
If the module will be triggered by the PGM output, in the “Config 3” screen, set “V-
Voice unit” and “G-delayed PGM” to “+” (see section 5.4.3).
If the module will be triggered by the SMOKE output, in the “Config 5” screen, set
“S-delayed SMOKE” to “+” (see section 5.4.5).
This will cause the control panel to play the recorded messages and to delay the
triggering of the output.
1
You cannot program a delay for the PGM output and the SMOKE output together. In such a case, the
system ignores the SMOKE delay.
+V
SMOKE PGM
SRN
OUTPUTS
-
1
KEYPAD
O UT
-
AUDIO
IN
2
3
4
+
IN
OUT
-
+
Control panel
B
lu
e
R
e
d
B
la
c
k
G
re
e
n
M
1
M
2
G
N
D
+
1
2
V
A
u
d
io
VU-20(U)
C
O
N
T
.
V
(+)
AUDIO
IN
VU-20(U)
GND
)
-
(
PGM/
SMOKE
B
lu
e
R
e
d
B
la
c
k
G
re
e
n
Y
e
llo
w
W
h
it
e
Loose
Control panel