Captain 6 Installation Guide
30
Par.
Onscreen
When setting to “+”
T
Tone Dial
“+” The control panel will use tone dialing
“-” The control panel will use pulse dialing
5.4.3
Config 3
Technician code
Select:
CPTN XX en 6.10
System config.
:
ENTER/NEXT/END
X3:
SDVKKG Not Used
-+---- Config 3
set the parameters
See section 3.2.4 for programming instructions of the parameters bar.
Par.
Onscreen
When setting to “+”
S
Not in use
-
D
Dnld. Disa
Remote access via the Comax is disabled by default (the
parameter is set to “+”)
To enable it:
1.
Set the parameter to “-”.
2.
On the first time remote access is required, when calling
the system, the end user must enter the MASTER code and
press the
key twice.
3.
This procedure is valid for 4 minutes only. After that, if
access has not been established and is still required, it
must be repeated.
V
VoiceUnit
A VU-20N/U voice module is connected to the system.
Instead of sounding the synthesized alarm tone when calling the
customer, a recorded message will be played.
In addition to enabling this parameter, set to “+” “G - Del. PGM”
in this screen and “G - PGM” in the “Zone responses” screen (see
section 5.1.3).
K
Zone6=key
Zone #6 is set as KEY switch input.
K
Key=State
“+”: The KEY switch is set as 2-state key (ON/OFF, toggle).
“-”: The KEY switch is set as momentary/wireless remote key.
G
Del. PGM
Delayed PGM: the PGM output will be switched to “-” only after
the system completes dialing, so that the voice module recorded
message will not be played before the call is answered.
5.4.4
Config 4
Technician code
Select:
CPTN XX en 6.10
System config.
:
ENTER/NEXT/END
X4
LLDASSLine Check
------ Config 4
set the parameters
See section 3.2.4 for programming instructions of the parameters bar.
ENTR
ENTR
ENTR
ENTR
ENTR