Captain 6 Installation Guide
32
Par.
Onscreen When setting to “+”
L
Listen-in
A MIC-200 microphone is connected to the control panel.
The microphone will be triggered via the PGM or SMOKE
outputs (see section 5.3). This feature can be triggered
only in the ContactID
©
protocol.
The trigger for the listen-in is 3 minutes long.
S
Del.Smoke SMOKE output delay. See section 5.3
4
RXN-406
The RXN-406 or RX-6 keypads are in use. Neither one of these
keypads cannot be used together with the RX-130 LED keypad.
5.4.6
Config 6
Technician code
Select:
CPTN XX en 6.10
System config.
:
ENTER/NEXT/END
X6
PDX User 8=Panic
--- Config 6
set the parameters
See section 3.2.4 for programming instructions of the parameters bar.
Par.
Onscreen
When setting to “+”
P
8=Panic
Entering User code #8 will send a PANIC alarm
D
Arm.Dis.fail
The system cannot be armed with AC, low battery or phone fault
X
Not Used
-
5.5
System responses
Technician code
Select:
CPTN XX en 6.10
System Response
ENTER/NEXT/END
SPGF Siren
---- Panic Resp
SPBG Siren
---- AC fail
Response time:
240
SPBG Siren
---- Bat fail
SPBG Siren
---- Phn.fail
Response time:
0
SPBG Siren
---- Zon.fail
STPGD Sirencheck
---- Key stat
Set the responses to some system events and faults.
Each parameter screen has 4 or 5 parameters, each one stands for a potential response
to the event that is displayed on the same screen, e.g., “zone fault”.
In the response time screens, set a delay for the control panel to report the on event. A
zero time is no delay.
5.5.1
PANIC alarm response
See section 3.2.4 for programming instructions of the parameters bar.
Par.
Onscreen When setting to “+”
S
Siren
The siren will be triggered
P
Communic. The alarm will be reported to the Monitoring Station and the end user
via the phone, and to the Monitoring Station via the Radio too.
G
PGM
The PGM output will be triggered
F
FIRE
The SMOKE output will be triggered
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR