Captain 6 Installation Guide
31
Par.
Onscreen When setting to “+”
L
Line Check
The system will perform periodic dial tone checks when it is armed
5
L
Chk in off
The system will perform periodic dial tone checks when it is disarmed
D
Dbl reprt
“Double report” parameter. See the following section
A
Reprt all
“Double report” parameter. See the following section
S
Smke inv.
The smoke output will normally be disconnected, and switched to
GND when the alarm is set off.
To set the output’s trip time, see section 5.3.
S
2 rng snp
2-ring line snapping (“Answering machine override”) is enabled.
The process of calling the control panel is as follows:
1.
Call the system, wait for 2 rings and hang up;
17.
Wait 10 seconds;
18.
Call the system again;
19.
The system will pick up the call immediately.
5.4.4.1
Double report parameters (D/A)
The next table describes to two “Double report” parameters taken from the “Config 4”
previous screen.
When “Double report” is enabled, telephone numbers #1 & #2 of the Monitoring Station
will be of station #1, and numbers #3 and #4 will be of station #2 (see section 5.2.1).
D
A Description
-
- No “Double report”
+
- “Double report” as follows:
1.
All events are reported to Monitoring Station #1;
2.
Monitoring Station #2 is reported only on arming, disarming, faults and tests.
+
+ “Double report” is fully enabled: all events are reported to Monitoring Station #1 & #2
5.4.5
Config 5
Technician code
Select:
CPTN XX en 6.10
System config.
:
ENTER/NEXT/END
X5
BKB2LS4ByPsReprt
------- Config 5
set the parameters
See section 3.2.4 for programming instructions of the parameters bar.
Par.
Onscreen When setting to “+”
B
ByPsReprt
Bypassing a zone will be reported to the Monitoring Station
K
RX130Kbrd The RX-130 keypad is in use. This keypad cannot be used
together with the RXN-406 or the RX-6 LED keypads.
B
ByPsRqest
The system cannot be armed if any zone is open, including
“Delayed” and “Entry Followers” zones.
2
EOL 2 Res
All EOL resistor loops have 2 resistors and can indicate on cut
and short.
5
Regardless of this parameter and the next one, the control panel checks the line voltage every time it is
armed and disarmed, and once every 24 hours.
ENTR
ENTR