Captain 6 Installation Guide
22
5.
PROGRAMMING THE SYSTEM
5.1
Zones
5.1.1
Zone sensitivity
Technician code
Select:
CPTN XX en 6.10
Sens. <X 50 mS>
ENETR/NEXT/END
Sens. <X 50 mS>
Z 1:8 Z 2:8
zone #1 sensitivity OR
to set zone #2 sensitivity OR
to the next zones.
Zone sensitivity is the time in milliseconds a zone must be triggered, before it can trigger
the alarm. If the zone is opened for a shorter time, the control panel ignores that.
Zone sensitivity is set per zone.
The sensitivity is set in a number that is multiplied by 50. For example, entering “8”
means a sensitivity of 8 times 50, that is 400 milliseconds (0.4 seconds).
The minimum triggering time is 50 milliseconds and the maximum is 12,500 (12.5
seconds). In the values that can be set, the minimum is “1” and the maximum is “250”.
The zone sensitivity is set in increments of 50 milliseconds (0.05 seconds).
5.1.2
Zone characteristics
Technician code
Select:
CPTN XX en 6.10
Zone character.:
ENTER/NEXT/END
BOFHIDE Bypass
-+-++-- Zn.Char1
set the characteristics of zone #1
Set the characteristics of each zone: delay, N.O./N.C., etc.
The first screen is zone #1 screen. You can enter any other zone number and program
its characteristics. (See how in section 3.2.3).
To confirm and progress to the next zone,
The characteristics are set per zone independently.
To progress to the next zone without saving,
The following is a description of the zone characteristics:
Par. Onscreen
Characteristic description
B
Bypass
The zone is permanently bypassed and will not trigger the alarm at
any time, if violated.
O
N.O.
“Normally Open” zone
F
24 Hours
24-hour zone. The zone will trigger the alarm at any time, if violated,
regardless of system state: Armed, Disarmed, or Home
H
Active in
“Home” mode The zone will be armed when the “Home” mode is armed.
1
ON/OFF
ENTR
ENTR
ENTR
ENTR
ENTR