Operation
Operating Manual PSEN sg2c
1003267EN02
44
9.3
Remedy
Fault conditions are indicated by flashing the LEDs. Some errors are displayed through
periodic flashing (see table); with other errors it is possible to establish an error code
through the number of flashes.
Error
Cause
Remedy
Safety switch does not re
act, LED "Device" does not
light
Supply voltage missing/too
low
Check supply voltage and apply 24 V
"Safety Gate" LED flashes a
code and "Device" LED
flashes red
see section Error codes
see section Error codes
"Device" LED illuminates
red
Internal error
Please contact Pilz
"Input" LED flashes yellow,
only one safety output
switches
Only one channel of the in
put circuit is open (partial
operation)
Open both channels of the input circuit and
close them again
Signal output does not
switch when actuator is en
gaged, "SafetyGate" LED
does not light up
Actuator not detected
Insert actuator as far as it will go
Solenoid does not switch
Supply voltage or voltage
for solenoid operation is too
low, error in the wiring
}
Check voltages and apply 24 V, check wir
ing,
}
Increase voltage for solenoid to increase
tolerance,
}
reduce cable run,
}
Use cable with a greater conductor cross
section
Solenoid does not switch,
"SafetyGate" LED does not
light up
Actuator not detected
Insert actuator as far as it will go
Safety outputs do not switch Escape or auxiliary release
pin is not correctly in posi
tion
}
Check whether the LED "Lock / Area Safe"
flashes red
}
Position the escape or auxiliary release pin
as far as it will go
}
Perform reset
"Safety Gate" LED lights up
and guard locking element
is engaged, but the outputs
are not switching.
Wrong actuator, e.g. 1.1
coded actuators with 2.2
coded safety switch
Insert correct actuator
Error codes
Error codes are issued after 9ß0 seconds at the latest at the LED "Safety Gate". The num
ber of LED flashes corresponds to the error code. The error code consists of one digit. (4 x
flashing: error code 4). The flashing sequence is constantly repeated and separated from
each other by longer periods.