Installation
Operating Manual PSEN sg2c
1003267EN02
33
NOTICE
Inside the danger zone, the escape release pin must protrude at least 65
mm from the profile. After installation, the escape release must be checked
for proper operation. When shortening the escape release pin, the material
of the escape release must not exceed a temperature of 100 °C
65 mm
45 mm
Pin for escape release
with ball handle
Pin for auxiliary release
If the escape release is not to be used, the escape release pin can be shortened to a length
of 45 mm and then be used for the auxiliary release. The auxiliary release pin is also avail
able as an accessory (order no. 570 771).
NOTICE
Please note that the escape release pin must not be shorter than 45 mm, to
guarantee the full holding force.
6.2
Initial installation safety switch and handle unit
}
Check whether the present bolt tongue is correctly oriented at the handle unit. Standard
is righthand door hinge at delivery (leave of the door opens to the right).
}
Coat the thread of the ball handle with screw adhesive (e.g. Loctite 2700) and screw
firmly together with the handle unit by hand.
}
Install bolt tongue with handle unit:
–
Position the screwdriver in the slots of the limit stop mechanism provided (see "Un
lock bolt").
–
Press screwdriver towards the base plate to release the springloaded limit stop
mechanism.
–
Engage bolt tongue with handle unit in the actuator guide.
–
Ensure by moving backwards and forwards towards the limit stop that the handle
unit cannot be removed from the actuator guide.