Wiring
Operating Manual PSEN sg2c
1003267EN02
21
}
When calculating the max. cable run, remember to take into account the chapter "Notes
on cable run".
5.4
Terminal configuration
1
X2
3
5
7
9 11 13 15
2
4
6
8 10 12 14 16
1
X1
3
5
7
9 11 13 15
2
4
6
8 10 12 14 16
Terminal
PSEN sg2c3xxx
PSEN sg2c5xxxx
PSEN sg2c5xxxx
M12/5
X11 X21 linked intern
ally
+24 UB
+24 UB
+24 UB
X15 X25 linked intern
ally
0 V
0 V
0 V
X13
Safety output channel 1
Safety output channel 1
Safety output channel 1
X14
Safety output channel 2
Safety output channel 2
Safety output channel 2
X15 X25 linked intern
ally
Output pushbutton for ac
cess request [2]
Output pushbutton for ac
cess request [2]
Output pushbutton for ac
cess request [2]
X16 X26 linked intern
ally
Solenoid operation (24 V) Solenoid operation (24 V) Solenoid operation (24 V)
X17 X27 linked intern
ally
Solenoid operation (24 V) Solenoid operation (24 V) Solenoid operation (24 V)
X18 X28 linked intern
ally
Input for activating the
guard locking of the
safety gate
Input for activating the
guard locking of the
safety gate
Input for activating the
guard locking of the
safety gate
X19
Signal output for state of
the bolt tongue
Signal output for state of
the bolt tongue
Signal output for state of
the bolt tongue
X110
Emergency stop 1.1
Emergency stop 1.1
Emergency stop 1.1
X111
Emergency stop 1.2
Emergency stop 1.2
Emergency stop 1.2
X112
Emergency stop 2.1
Emergency stop 2.1
Emergency stop 2.1
X113
Emergency stop 2.2
Emergency stop 2.2
Emergency stop 2.2
X114
n.c
Pushbutton 3 LED3
n.c
X115
n.c
Pushbutton 4 LED4
Pushbutton 4 LED4