Function description
Operating Manual PSEN sg2c
1003267EN02
15
PSEN sg2c3xxx (3 pushbuttons)
[1] pushbutton 1: Pushbutton for activating the guard locking of the safety gate
[2] pushbutton 2: Pushbutton for access request and release of the safety gate
[3] ESTOP/ or section stop
Name key:
PSEN sg2c - 3 L X X 2.2*
3 pushbuttons = 3
Pushbutton illuminated = L
Pushbutton unilluminated = P
Key switch = B
E-STOP = E
Section stop = S
no pushbutton = C
Fully-coded
[1]
[2] [3]
*not included with all versions
Versions:
Pushbutton 1
Pushbutton 2
ESTOP/
Section stop
Coding
3LPE
Pushbutton
illuminated
Pushbutton
unilluminated
ESTOP
coded
3LBE
Pushbutton
illuminated
Key
switch
ESTOP
coded
3LPS
Pushbutton
illuminated
Pushbutton
unilluminated
Section
stop
coded
3LBS
Pushbutton
illuminated
Key
switch
Section
stop
coded
3LPC
Pushbutton
illuminated
Pushbutton
unilluminated
coded
3LBC
Pushbutton
illuminated
Key
switch
coded
3LPE 2.2
Pushbutton
illuminated
Pushbutton
unilluminated
ESTOP
fully coded