Environmental data
778010
788010
Condensation during operation
Not permitted
Not permitted
EMC
EN 61000-6-2, EN 61326-3-1, EN
61496-1
EN 61000-6-2, EN 61326-3-1, EN
61496-1
Vibration
In accordance with the standard
EN 60068-2-6
EN 60068-2-6
Frequency
10 - 55 Hz
10 - 55 Hz
Amplitude
0,35 mm
0,35 mm
Airgap creepage
In accordance with the standard
EN 60947-1
EN 60947-1
Overvoltage category
III / II
III / II
Pollution degree
2
2
Rated insulation voltage
250 V
250 V
Rated impulse withstand voltage
4 kV
4 kV
Protection type
Housing
IP40
IP40
Terminals
IP20
IP20
Mounting area (e.g. control cab-
inet)
IP54
IP54
Mechanical data
778010
788010
Mounting position
Any
Any
Mechanical life
10,000,000 cycles
10,000,000 cycles
Material
Bottom
PPO UL 94 V0
PPO UL 94 V0
Front
ABS UL 94 V0
ABS UL 94 V0
Top
PPO UL 94 V0
PPO UL 94 V0
Connection type
Screw terminal
Spring-loaded terminal
Mounting type
plug-in
plug-in
Conductor cross section with screw
terminals
1 core flexible
0,2 - 2,5 mm², 24 - 12 AWG
–
2 core with the same cross sec-
tion, flexible with crimp connect-
ors, no plastic sleeve
0,2 - 1 mm², 24 - 16 AWG
–
2 core with the same cross sec-
tion, flexible without crimp con-
nectors or with TWIN crimp con-
nectors
0,2 - 1,5 mm², 24 - 16 AWG
–
Torque setting with screw terminals
0,5 Nm
–
Conductor cross section with
spring-loaded terminals: Flexible
with/without crimp connector
–
0,2 - 1,5 mm², 24 - 16 AWG
Spring-loaded terminals: Terminal
points per connection
–
2
Stripping length with spring-loaded
terminals
–