PMUT X1P
Operating Manual PMUT X1P
20587-EN-06
24
Times
778010
788010
Switch-on delay
With monitored start with rising
edge typ.
40 ms
40 ms
With monitored start with rising
edge max.
80 ms
80 ms
Muting lamp 1 typ.
25 ms
25 ms
Muting lamp 1 max.
30 ms
30 ms
Muting lamp 2
60 ms
60 ms
Muting typ.
35 ms
35 ms
Muting max.
80 ms
80 ms
Delay-on de-energisation
With E-STOP typ.
8 ms
8 ms
With E-STOP max.
20 ms
20 ms
With power failure typ.
490 ms
490 ms
With power failure max.
700 ms
700 ms
After safety function is triggered
typ.
15 ms
15 ms
After safety function is triggered
max.
20 ms
20 ms
with power failure during muting
typ.
125 ms
125 ms
with power failure during muting
max.
180 ms
180 ms
Recovery time at max. switching
frequency 1/s
After E-STOP
320 ms
320 ms
After power failure
1 s
1 s
after muting sensors off
300 ms
300 ms
Waiting period with a monitored
start
With rising edge
300 ms
300 ms
Min. start pulse duration with a
monitored start
With rising edge
40 ms
40 ms
Supply interruption before de-ener-
gisation in the input circuit
5 ms
5 ms
Supply interruption before de-ener-
gisation
20 ms
20 ms
Simultaneity, channel 1 and 2 max.
3 s
3 s
Environmental data
778010
788010
Climatic suitability
EN 60068-2-78
EN 60068-2-78
Ambient temperature
Temperature range
-10 - 55 °C
-10 - 55 °C
Storage temperature
Temperature range
-40 - 85 °C
-40 - 85 °C
Climatic suitability
Humidity
93 % r. h. at 40 °C