PMUT X1P
Operating Manual PMUT X1P
20587-EN-06
15
}
Mechanical and optoelectronic sensors (safety light beam devices, safety light grids)
are suitable for use.
}
The safety contacts can be used to shut down the potentially hazardous movement.
}
Only safe contact outputs (e.g. from safety light grids) may be used at S51-S52 and
S61-S62. Do
not
connect safety light grids with semiconductor outputs.
}
The cables for connecting the muting sensors to terminals S1/S3 and S2/S4 must be
laid in separate sheathed cables!
}
Only use muting lamps that have a luminous area of at least 1cm
2
and a luminosity of at
least 200 cd/m
2
, in accordance with EN 61496-1.
}
When connecting magnetically operated, reed proximity switches, ensure that the max.
peak inrush current (on the input circuit) does not overload the proximity switch.