5.1
Installation location
The following requirements apply to the installation location:
}
The installation location must be free of any aggressive substances and any electrically
conductive atmosphere
}
The substructure must be even, free of vibrations and resistant to warpage
}
Sufficient heat dissipation must be ensured; for this purpose, ensure compliance with
the permitted surrounding temperature and, as needed, provide additional cooling for
the motor, such as by using a forced ventilation unit
}
If using a forced ventilation unit, ensure compliance with the minimum clearance of the
air intake
Type
Forced ventilation unit
Minimum clearance x
Fmin
[mm]
SZ.4x
FL4
20
SZ.5x
FL5
20
SZ.7x
FL7
30
SZ.8x
FL8
30
The following graphics show permitted installation positions IM B5, IM V1 and IM V3.
IM V1
IM V3
IM B5
In installation position IM V3, take special care that no fluid from attachments can get into
the motor bearings.