Installation
Operating Manual PMCtendo SZ
1002405-EN-04
20
5.2.2
Installing the motor
a
Align the coupling correctly. Misalignment leads to impermissible vibrations and to the
destruction of ball bearings and coupling!
a
Avoid mechanically constrained motor shaft mounting. A rigid coupling and/or exces-
sive additional bearings (e.g. in the gear unit) can put excessive stress on the motor
shaft.
a
Thoroughly remove any corrosion protection agent and/or dirt from the motor shaft. Use
commercially available solvents to do so. Make sure that solvent does not come in con-
tact with the sealing lips of the shaft seal rings. Otherwise, material damage may occur.
a
Prevent contact between temperature-sensitive parts and the motor. The surface of the
motor can reach temperatures that are significantly above 65 °C through operation.
a
If you remove the eyebolts after installation, you must seal the tapped hole in a durable
way according to the protection class of the motor.
Содержание PMCtendo SZ Series
Страница 1: ...PMCtendo SZ Operating Manual 1002405 EN 04...