Technical data
Operating Manual PMCtendo SZ
1002405-EN-04
46
9.3
Ambient conditions
Feature
Description
Surrounding temperature for transport/storage
−30 °C to +85 °C
Surrounding temperature for operation
−15 °C to +40 °C
Installation altitude
≤ 1000 m above sea level
Shock load
≤ 50 m/s
2
(5 g), 6 ms in accordance
with EN 60068-2-27
Notes
}
Pilz synchronous servo motors are not suitable for potentially explosive atmospheres in
accordance with (ATEX) Directive2014/34/EU.
}
Secure the power cables close to the motor so that vibrations of the cable do not place
impermissible loads on the motor plug connector.
}
Note that the braking torques of the holding brake (optional) may be reduced by shock
loading.
}
Also take into consideration the shock load of the motor due to output units (such as
gear units and pumps) which are coupled with the motor.
9.4
Forced ventilation unit
Type
Forced
ventilation
unit
U
N,F
[V]
I
N,F
[A]
P
N,F
[W]
q
v,F
[m³/h]
L
p(A)
[dBA]
m
F
[kg]
Protec-
tion
class
SZ.4x
FL4
230 V ± 5%,
50/60 Hz
0.07
10
59
41
1.4
IP44
SZ.5x
FL5
0.10
14
160
45
1.9
IP54
SZ.7x
FL7
0.10
14
160
45
2.9
IP54
SZ.8x
FL8
0.20
26
420
54
5.0
IP55
9.5
Feedback connection
EnDat 2.2
Type
Code
Measuring
method
Revolu-
tions
Resolution
Position
per
revolution
Operating
voltage
range
ECI 1118-G2 1
Inductive
–
18 bit
262144
3.6 – 14 V
EQN 1135
2
Optical
4096
23 bit
8388608
3.6 – 14 V
HIPERFACE DSL
Type
Code
Measuring
method
Revolu-
tions
Resolution
Position
per revolu-
tion
Operating
voltage
range
EKM36
7
Optical
4096
20 bit
1048576
7 – 12 V
Содержание PMCtendo SZ Series