VICES PRESSURE-SENSORS SETTING
The screen will appear in the event of manual input on the settings screen or if the PLC signal fades during the vice clamping. The
machine immediately interrupts its operation and switches off the hydraulic unit, otherwise it may result in a hydraulic system
leakage. Upon pressing the failures screen, a screen with settings appears, on which you can check the operation of pressure
sensors.
You can check the function of pressure switches after you start the hydraulic unit. When the vice is closed, the lamp must light up. If
the vice is closed and the lamp is off, you have to adjust the pressure switch (or identify another fault in the circuit). After releasing the
vice, the lamp must go off. Press the vice icon to change the state of the vice – OPEN/CLOSED To exit the screen, first turn off the
hydraulic unit and then press the ESC button.
Pressure switch settings
Insert the workpiece in the vice, switch on the hydraulic unit and clamp the right vice. Light-bulb symbol on the PLC must light up. If it
does not light up or if it is flashing, you have to adjust the TS 2 pressure switch (TS 1 for the left vice).
Turn the adjusting screw on the pressure switch (remove the black rubber cap, the screw is between two Faston connectors) to the
right.
Such operations may be carried out only by persons with electrician qualifications! Danger of short circuit of 24V
contacts!
Release the right vice. If the lamp is on while the vice is unclamped, turn the adjusting screw to the left.
Correct settings: Clamped vice - the lamp is ON
Unclamped vice - the lamp is OFF
Clamping or detachment of the left vice must not affect the signalization of clamping of the right vise. After deleting the error, you can
continue with the interrupted cycle. Similarly, we set the left vice with pressure switch TS 1.
VICE PRESSURE SWITCH
WORM CHIPS TRANSPORTER
min
min
1
3
START/STOP
coolant pump - for machine cleaning
START/STOP
chips transporter - for machine cleaning
If the chips transporter is connected, tick as active
Here you can set the time interval of chips
transporter operation and the time interval
of its inactivity while the saw blade is on.
If the conveyor for cut pieces is connected, tick as active
sec.
3
There is a possibility to set the time interval
in which the conveyor for the cut pieces
should be in operation (after cutting the
material).
Screen WORM CHIPS TRANSPORTER becomes activated
after pressing the WORM CHIPS TRANSPORTER button on
the MACHINE SETUP screen.
WORM CHIPS TRANSPORTER
0 9 : 2 0 : 0 3
0 8 / 1 0 / 2 0 1 6
min
min
1
3
sec.
3
VICES PRESSURE-SENSORS SETTING
0 9 : 2 0 : 0 3
0 8 / 1 0 / 2 0 1 6
L
R
ESC
Optical sensor of material ending
Содержание ARG 260 CF-NC automat