background image

VICES PRESSURE-SENSORS SETTING

The screen will appear in the event of manual input on the settings screen or if the PLC signal fades during the vice clamping. The 
machine  immediately  interrupts  its  operation  and  switches  off  the  hydraulic  unit,  otherwise  it  may  result  in  a  hydraulic  system 
leakage. Upon pressing the failures screen, a screen with settings appears, on which you can check the operation of pressure 
sensors.

You can check the function of pressure switches after you start the hydraulic unit. When the vice is closed, the lamp must light up. If 
the vice is closed and the lamp is off, you have to adjust the pressure switch (or identify another fault in the circuit). After releasing the 
vice, the lamp must go off. Press the vice icon to change the state of the vice – OPEN/CLOSED To exit the screen, first turn off the 
hydraulic unit and then press the ESC button.

Pressure switch settings

Insert the workpiece in the vice, switch on the hydraulic unit and clamp the right vice. Light-bulb symbol on the PLC must light up. If it 
does not light up or if it is flashing, you have to adjust the TS 2 pressure switch (TS 1 for the left vice).
Turn the adjusting screw on the pressure switch (remove the black rubber cap, the screw is between two Faston connectors) to the 
right. 

Such operations may be carried out only by persons with electrician qualifications! Danger of short circuit of 24V 

contacts! 

Release the right vice. If the lamp is on while the vice is unclamped, turn the adjusting screw to the left.

Correct settings:  Clamped vice - the lamp is ON

Unclamped vice - the lamp is OFF

Clamping or detachment of the left vice must not affect the signalization of clamping of the right vise. After deleting the error, you can 
continue with the interrupted cycle. Similarly, we set the left vice with pressure switch TS 1.

VICE PRESSURE SWITCH

WORM CHIPS TRANSPORTER

min

min

1

3

START/STOP 

coolant pump - for machine cleaning

START/STOP 

chips transporter - for machine cleaning

If the chips transporter is connected, tick as active

Here you can set the time interval of chips 
transporter operation and the time interval 
of its inactivity while the saw blade is on.

If the conveyor for cut pieces is connected, tick as active

sec.

3

There is a possibility to set the time interval 
in  which  the  conveyor  for  the  cut  pieces 
should  be  in  operation  (after  cutting  the 
material).

Screen WORM CHIPS TRANSPORTER becomes activated 
after pressing the WORM CHIPS TRANSPORTER button on 
the MACHINE SETUP screen. 

WORM CHIPS TRANSPORTER

0 9 : 2 0 : 0 3

0 8 / 1 0 / 2 0 1 6

min

min

1

3

sec.

3

VICES PRESSURE-SENSORS SETTING

0 9 : 2 0 : 0 3

0 8 / 1 0 / 2 0 1 6

L

R

ESC

Optical sensor of material ending

Содержание ARG 260 CF-NC automat

Страница 1: ...G 300 DCT CF NC automat ARG 330 CF NC automat ARG 330 DC CF NC automat ARG 520 DC CF NC automat 1 PART INSTRUCTION MANUAL Pilous p sov pily spol s r o elezn 9 619 00 Brno Czech Republic tel 00 420 543...

Страница 2: ......

Страница 3: ...ction 1 2 Packing 1 3 Disassembly Repacking 1 4 Disposal 2 Technical Data 3 Installation 3 1 Space Requirements 3 2 Removal of Temporary Transport Beams and Fixation of the Machine 3 3 Machine Install...

Страница 4: ...r any other inappropriate environment Wear parts see the Letter of Guarantee Potential claims concerning guarantee and after guarantee repairs should be made by phone post or e mail to the address see...

Страница 5: ...or and secure it against restart before you start handling the saw blade Only persons with adequate electrician qualifications are allowed to open protective covers of the electrical equipment and to...

Страница 6: ...raps to prevent movement Thread the straps through the yellow consoles located in the corners of the machine see picture It is recommended to transport and lift the machine only with a forklift Forks...

Страница 7: ...3 kW Hydraulic oil approx 26 l 1450 kg 2560 2220 2080 850 mm 3 approximately 35 litres 90 60 60 45 45 400 V 50 Hz 550 W ARG 520 DC CF NC 180 170 180x120 3150x27x0 9 355 mm 300 285 205x290 Hydraulic o...

Страница 8: ...or near the working area of the machine No unauthorised personnel may enter the danger zone To prevent injury the danger zone must also be level and free from any foreign objects and obstacles Recomm...

Страница 9: ...F NC ARG 300 DCT CF NC ARG 330 CF NC ARG 330 DC CF NC ARG 520 DC CF NC ARG 260 CF NC A max B max C max 1330 mm 1790 mm 2215 mm 2370 mm 2280 mm 2980 mm 2970 mm 2970 mm 2970 mm 2970 mm 2970 mm 2660 mm 1...

Страница 10: ...n temperatures below 5 C the conventional coolants should be replaced by coolants designed for respective temperatures In addition to that replace the oil in the hydraulic unit for a less viscous one...

Страница 11: ...e C saw blade tensioning D gearbox E motor F fixed vice G movable vice H base I arm J control panel K table L chip tray M fixed bar N movable bar O hydraulic cylinder of the vice P hydraulic cylinder...

Страница 12: ...gearbox E motor F fixed vice G movable vice H base I arm J control panel K table L chip hopper chip bin M cleaning brush N fixed bar O movable bar P hydraulic cylinder of the vice Q hydraulic stroke c...

Страница 13: ...J S ARG 520 DC CF NC automat C A D E F G H K L M N O P Q R S T W X...

Страница 14: ...controlled hydraulically The servo motor and the ball screw ensure high speed and maximum accuracy of material feeding Maximum length of a single feed is 500 mm in ARG 520 DC CF NC 600 mm The control...

Страница 15: ...ting LAMP 24 V Indicator lamp indicates that the CONTROL PANEL is under power supply of 24 V You can change the cutting speed using a saw blade speed controller using a frequency converter on the cont...

Страница 16: ...ction manual because they possess the same function on all screens After you press the TIME box a screen with data about the operating status of the machine appears applies to all screens in all modes...

Страница 17: ...rview of the active series Hydraulic unit Start Stop Press the hydraulic unit START STOP icon to start or stop the hydraulic unit START Starting the automatic cycle After pressing the START button the...

Страница 18: ...press the START button of the WORKING CYCLE in the SEMI AUTOMATIC MODE to perform the cycle After finishing the vice remains open If the vice is closed press the START button of the WORKING CYCLE in t...

Страница 19: ...different function that has not been activated yet the button of the preceding function will start flashing to indicate error START STOP uplift or descent of the arm Saw blade upwards Saw blade downw...

Страница 20: ...s it is possible to set up the following series without interrupting the cycle If the editing of the next series takes too long and the machine completes the previous series in the meantime cutting of...

Страница 21: ...g it while feeding the material by the set value After finishing the cut the vice will feed the material by the set value If it is no longer possible to feed the material towards 0 mm the vice move ag...

Страница 22: ...SERIES X 12 Clearly displays the complete status and a list of all series SERIES LIST 1 2 0 9 2 0 0 3 0 8 1 0 2 0 1 6 ESC SERIES LENGTH PIECES FEED ACT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 357 159 456...

Страница 23: ...ess the DATE SETTING button to enter the specified date into the system MACHINE SETUP LANGUAGE switch to the screen selection of several languages UNIT possibility of setting the unit length in mm or...

Страница 24: ...ars on top and is not deleted In the case of a new failure the previous failure will move to a line below The system stores 200 failures You can browse through the list using buttons Failures appear i...

Страница 25: ...is between two Faston connectors to the right Such operations may be carried out only by persons with electrician qualifications Danger of short circuit of 24V contacts Release the right vice If the...

Страница 26: ...t height settings If the current position of the arm does not correspond to a check measurement by a gauge tape measure carry out the calibration of arm uplift position measurement 1 Input 0 in the co...

Страница 27: ...witch TS Pressure switch Blue square signalizes that the device is switched on More about failure reporting in chapter Failures PERFORM KERF NO YES INFORMATIONAL POP UP WINDOWS Informational pop up wi...

Отзывы: