Inputs:
0
- IRC A
1 - IRC B
2 - Receiver of the optical gate for the detection of the end of the
material
3 - Limit switch - fixed vice runs idle BP7
4 - limit switch - the movable vice runs idle BP3
5 - Limit switch - lower position of the arm BP6
6 - Pressure switch of the fixed vice TS2
7 - Pressures switch of the movable vice TS1
8 - Motor starter of the hydraulic motor FQ1
9 - Motor starter of the cooling pump FQ3
10 - Safety relay is in a fault condition
11 - Motor starter of the chip conveyor motor FQ5
12 - Limit switch of the track cover BP4
13 - Limit switch - blade tensioning BP2
Outputs:
0 - Arm up
1 - Arm down
2 - Clamping of the left vice
3 - Clamping of the right vice
4 - Motor of the hydraulic unit
5 - Cooling pump
6 - Oil mist lubrication
7 - Failure indicator
8 - Motor of the chip conveyor
9 - Illumination
SYSTEM 1
SYSTEM 2
ESC
Settings (calibration) of the arm uplift height measurement
(only in ARG 300 DCT CF-NC automat, ARG 330 DC CF-NC automat, ARG 520 DC CF-NC automat)
X = 80 mm
correction 20 mm
Y
= 100 mm
end
position
In order to ensure efficient cutting, the arm uplift should be set
just above the cut material (arm uplift height settings). If the
current position of the arm does not correspond to a check
measurement by a gauge (tape measure), carry out the
calibration of arm uplift position measurement.
1 - Input 0 in the correction.
2 - Press the green SAW BLADE DOWNWARDS button - the
arm will descend into the end position, its position will reset and
the arm will travel to 100mm value.
3 - Measure the height (x) at the fixed jaw, to which the saw blade
travelled, enter the difference into the correction and repeat from
the step 2.
E.g. if you measure X = 80mm, 100 - 80 = 20, set a 20 mm
correction. Measure the arm uplift height X again and if needed,
carry out another correction.
SYSTEM 1
0 9 : 2 0 : 0 3
0 8 / 1 0 / 2 0 1 6
Version of program:
PWR
RUN
ERR
I/O
SD
BAT
SL1
SL2
TM4
ETH
CAN_R
CAN_E
IN
OUT
TM241CEC24T
PROGRAM
BATTERY
charge level
100 %
Total feed
45.12
(mm)
2.49
SA
Z
RL
R1 R1a R1b RLx
0
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
10 11
12 13
0
1
2
3
4
5
6
7
8
9
SYSTEM 2
0 9 : 2 0 : 0 3
0 8 / 1 0 / 2 0 1 6
SYSTEM
SERVOINVERTER
LX 32
FREQUENCY INVERTER
ATV 32
4 - RDY
12
Reset
ITH (M2)
12.1
(A)
6 - run/hALt
Reset
Home
Absolute Movement
Speed without material Speed with material
1000
1 6 0 0
400
8 0 0
Operating Mode Jog
position (mm)
Direction max
Direction min
500.0 - 0.0
0.00
12
0%
12
12
0
CORRECTION
335
R e s e t I R C
HEIGHT
0
0
( m m )
( l m p )
Alarmy Reset
Zatížení
serva
0%
Содержание ARG 260 CF-NC automat
Страница 2: ......