DT2011646-00
6.14 REMOTE CONTROL (OPTIONAL)
Fig. 44
On request the stove may be supplied with a remote control, which can
be used to govern certain stove functions.
-
Startup/Shutdown:
by pressing the two + keys simultaneously the
stove can be turned on or off.
-
Power level:
when operating normally, pressing the + and - keys
above the flame symbol will select one of the four power levels of
the stove.
-
Temperature:
when operating normally, pressing the + and -
keys above the thermometer symbol will select the desired room
temperature (44° F and 86° F - 7° C and 30° C).
DT2010994-00
6.15 SAFETy dEvICES
a
During operation some parts of the stove (door, handle, ceramic parts) can reach high temperatures.
Remember to maintain the safety distances indicated previously.
Be careful,
take all due precautions
and always comply with the instructions.
If during operation smoke leaks from any part of the stove or the flue, shut the stove down immediately and ventilate the room. When the stove has
cooled, check for the cause of the leak and if necessary call in specialist personnel.
The stove is fitted with several safety devices to guarantee safe operation.
a
The safety devices are fitted to eliminate the risk of injury to people and pets and damage to property. Tampering or work carried out
by unauthorised personnel can jeopardise this function.
d
IN CASE OF ANY ALARM SIGNALS DO NOT UNPLUG THE STOVE: JUST TURN THE UNIT OFF.
Possible warnings of problems
Simple operating problems can usually be resolved with the help of the following pages.
Description of activity
Display
Connected to the flue gas outlet, its function is to control the vacuum inside the outlet
duct so that the stove can be used in all safety.
If correct operating conditions in the flue gas outlet change (incorrect installation,
blockages or obstructions in the flue, poor maintenance, unfavourable weather
conditions such as persistent wind, etc.) the pressure switch cuts off the power supply
to the fuel-loading auger, thereby stopping the supply of pellets to the grate and
starting the stove shutdown process.
- The readout “
ALF 1
” appears in the STOVE STATUS mode.
- The readout “
SAFETY SMOKE
“ appears on the display.
- After approx. 60 seconds the alarm sounds (if activated).
SAFETY
SMOKE
WHAT TO DO:
- Shut down the stove by holding the ON/OFF key down for several seconds.
- The alarm stops.
- Wait until you are sure that combustion of any pellets remaining in the grate has
stopped.
- Wait until the stove has cooled down, then check for and remove whatever has
caused the safety device to be triggered. Finally, after having cleaned the grate
restart the stove by pressing the ON/OFF key.